on Chainage 1.000 of Kot Randhar Badhani tall motor road (Mayali Randhar motor road)
In District Rudraprayag Under PD Rudraprayag Division
Critical Report on Bridge Condition
Form Filled By Satpal Singh Rangar [42270313M01710]
Inspection Team
Detail Report
# | Parameter | Problem ? | How Bad? | How Much? | |
---|---|---|---|---|---|
1 | ROAD APPROCHES AND DECK Component Weightage 10 | ||||
A- ROAD SURFACE NEAR BRIDGE | |||||
a) Bumpy road surface near bridge? | Not Applicable | -- | -- | -- | |
B- DRAINAGE | |||||
a) Badly built road drainage near bridge? | Not Applicable | -- | -- | -- | |
b) Blocked or damaged road drains? | Not Applicable | -- | -- | -- | |
c) Water on the deck? | Not Applicable | -- | -- | -- | |
d) Blocked or damaged deck drains? | Not Applicable | -- | -- | -- | |
C- WEARING COAT | |||||
CONCRETE WEARING COURSE | |||||
a) Cracking? | NO Problem | -- | -- | 0 | |
b) Spalling? | NO Problem | -- | -- | 0 | |
c) Reinforcement exposed? | NO Problem | -- | -- | 0 | |
d) Poor concrete? | NO Problem | -- | -- | 0 | |
e) Wear of surface due to small stones? | NO Problem | -- | -- | 0 | |
D- KERBS & FOOTPATHS | |||||
a) Loose railing fixtures? | Yes | Bad | Some Qty | 5 | |
a) Damaged or loose kerbs? | Not Applicable | -- | -- | -- | |
2 | PARAPETS, RAILINGS AND CRASH BARRIERS Component Weightage 10 | ||||
a) Impact damaged? | NO Problem | -- | -- | 0 | |
b) Loose or damaged fixings? | Yes | Bad | Some Qty | 5 | |
c) Loose base of posts? | Yes | Bad | Some Qty | 5 | |
d) Damaged coatirig or paint on steel surface? | Yes | Bad | Some Qty | 5 | |
e) Corrosion on steel surface? | Yes | Bad | Some Qty | 5 | |
f) Cracking on Masonary Parapets? | NO Problem | -- | -- | 0 | |
g) Movement or bending of parapet? | NO Problem | -- | -- | 0 | |
h) Poor pointing/ Plaster on parapet? | Yes | Bad | Some Qty | 5 | |
i) Deterioration of bricks or stones? | NO Problem | -- | -- | 0 | |
3 | EXPANSION JOINT AT ABUTMENTS & PIERS Component Weightage 10 | ||||
a) Damage to concrete of deck end or dirt wall near joint? | NO Problem | -- | -- | 0 | |
b) Debris or vegetation in joint? | Yes | Bad | Some Qty | 5 | |
c) Loose or damaged fixtures? | NO Problem | -- | -- | 0 | |
d) Damage or corrosion to metal parts? | Yes | Not So Bad | Not Much Qty | 1 | |
e) Damage to rubber waterseals? | Not Applicable | -- | -- | -- | |
4 | RIVER Component Weightage 10 | ||||
A- BLOCKAGES IN WATERWAY | |||||
a) Debris against piers or abutments? | Yes | Bad | Some Qty | 5 | |
b) Remains of old bridge under or upstream of the bridge? | NO Problem | -- | -- | 0 | |
c) Fencing or buildings under bridge? | NO Problem | -- | -- | 0 | |
d) Trees or bushes.growing under bridge? | Yes | Bad | Some Qty | 5 | |
B- CHANGE IN RIVER COURSE | |||||
a) River changing path upstream of bridge? | NO Problem | -- | -- | 0 | |
b) New islands forming upstream of bridge? | NO Problem | -- | -- | 0 | |
C- RIVER TRAINING WORKS | |||||
a) River attack beyond the upstream end of river training works? | NO Problem | -- | -- | 0 | |
b) Damage to walls? | NO Problem | -- | -- | 0 | |
c) Loss of pitching? | NO Problem | -- | -- | 0 | |
d) Damage to crates, timber, fencing, etc.? | NO Problem | -- | -- | 0 | |
e) Damage to trees? | NO Problem | -- | -- | 0 | |
5 | SUPERSTRUCTURE Component Weightage 60 | ||||
STEEL TRUSSES | |||||
General | |||||
a) Impact damage to girders, trusses or bracings? | NO Problem | -- | -- | 0 | |
b) Debris or vegetation on beams, girders, trusses bracings or joints? | Yes | Not So Bad | Some Qty | 2 | |
c) Water coming through the deck? | NO Problem | -- | -- | 0 | |
d) Water from the deck drainage flowing on to girders, trusses, beams or bracings? | NO Problem | -- | -- | 0 | |
e) Not enough vertical & horizontal clearances? | NO Problem | -- | -- | 0 | |
STEEL TRUSSES | |||||
a) Deterioration of paint or galvanising? | Yes | Bad | Some Qty | 5 | |
b) Corrosion? | Yes | Not So Bad | Not Much Qty | 1 | |
c) Bends in members? | NO Problem | -- | -- | 0 | |
d) Bent or damaged joints? | NO Problem | -- | -- | 0 | |
e) Bent or damaged bracing? | NO Problem | -- | -- | 0 | |
f) Loose bolts or rivets? | NO Problem | -- | -- | 0 | |
g) Cracking of steel members? | NO Problem | -- | -- | 0 | |
STEEL UNDERSIDE OF DECK | |||||
a) Deterioration of paint or galvanising? | Yes | Bad | Some Qty | 5 | |
b) Corrosion? | Yes | Not So Bad | Not Much Qty | 1 | |
c) Bends in stringers or plates? | NO Problem | -- | -- | 0 | |
d) Loose bolts or rivets? | NO Problem | -- | -- | 0 | |
e) Cracking? | NO Problem | -- | -- | 0 | |
6 | BEARINGS Component Weightage 10 | ||||
METAL BEARINGS | |||||
a) Debris or vegetation around bearings? | NO Problem | -- | -- | 0 | |
b) Bad drainage? | NO Problem | -- | -- | 0 | |
c) Not enough room for the bridge span to move? | NO Problem | -- | -- | 0 | |
d) Bearing not seated properly? | NO Problem | -- | -- | 0 | |
e) Bridge span not seated properly on bearing? | NO Problem | -- | -- | 0 | |
f) Damaged bedding mortar? | NO Problem | -- | -- | 0 | |
g) Damaged or loose earthquake restraints? | NO Problem | -- | -- | 0 | |
METAL BEARINGS | |||||
a) Parts not properly seated? | NO Problem | -- | -- | 0 | |
b) Parts not free to move? | NO Problem | -- | -- | 0 | |
c) Problem with the lubrication system? | NO Problem | -- | -- | 0 | |
d) Sliding surfaces damaged? | NO Problem | -- | -- | 0 | |
e) Cracks or bends in metal parts/ Bearing? | NO Problem | -- | -- | 0 | |
f) Corrosion of metal parts? | NO Problem | -- | -- | 0 | |
7 | Right Side ABUTMENT, WING WALLS & RETAINING WALLS Component Weightage 10 | ||||
A- GENERAL | |||||
a) Erosion or scour at abutment? | NO Problem | -- | -- | 0 | |
b) Damage to foundation? | NO Problem | -- | -- | 0 | |
c) Movement of abutment? | NO Problem | -- | -- | 0 | |
d) Debris against abutment? | NO Problem | -- | -- | 0 | |
e) Vegetation growing on-or in abutment? | Yes | Bad | Some Qty | 5 | |
f) Scour near to retaining walls? | NO Problem | -- | -- | 0 | |
g) Movement of retaining walls? | NO Problem | -- | -- | 0 | |
h) Water leaking down through the expansion joint? | NO Problem | -- | -- | 0 | |
B- DRAINAGE SYSTEM | |||||
a) Not enough weepholes? | Not Applicable | -- | -- | -- | |
b) Weepholes not working? | Not Applicable | -- | -- | -- | |
c) Water leaking through the abutment? | Not Applicable | -- | -- | -- | |
C- CONCRETE WALLS | |||||
a) Cracking? | NO Problem | -- | -- | 0 | |
b) Spalling? | NO Problem | -- | -- | 0 | |
c) Corrosion of reinforcement? | NO Problem | -- | -- | 0 | |
d) Poor concrete? | NO Problem | -- | -- | 0 | |
D- MASONRY WALLS | |||||
a) Cracking? | NO Problem | -- | -- | 0 | |
b) Bulging? | NO Problem | -- | -- | 0 | |
c) Poor pointing? | NO Problem | -- | -- | 0 | |
d) Deterioration of bricks or stones? | NO Problem | -- | -- | 0 | |
E- EMBANKMENTS AND FILL IN FRONT OF ABUTMENT | |||||
a) Scour at base of slopes? | NO Problem | -- | -- | 0 | |
b) Slippage of fill? | NO Problem | -- | -- | 0 | |
c) Erosion of fill? | NO Problem | -- | -- | 0 | |
d) Cracking of road or embankment edge? | NO Problem | -- | -- | 0 | |
e) Piping failure of fill? | NO Problem | -- | -- | 0 | |
8 | Left Side ABUTMENT, WING WALLS & RETAINING WALLS Component Weightage 10 | ||||
A- GENERAL | |||||
a) Erosion or scour at abutment? | NO Problem | -- | -- | 0 | |
b) Damage to foundation? | NO Problem | -- | -- | 0 | |
c) Movement of abutment? | NO Problem | -- | -- | 0 | |
d) Debris against abutment? | NO Problem | -- | -- | 0 | |
e) Vegetation growing on-or in abutment? | Yes | Bad | Some Qty | 5 | |
f) Scour near to retaining walls? | NO Problem | -- | -- | 0 | |
g) Movement of retaining walls? | NO Problem | -- | -- | 0 | |
h) Water leaking down through the expansion joint? | NO Problem | -- | -- | 0 | |
B- DRAINAGE SYSTEM | |||||
a) Not enough weepholes? | NO Problem | -- | -- | 0 | |
b) Weepholes not working? | NO Problem | -- | -- | 0 | |
c) Water leaking through the abutment? | NO Problem | -- | -- | 0 | |
C- CONCRETE WALLS | |||||
a) Cracking? | NO Problem | -- | -- | 0 | |
b) Spalling? | NO Problem | -- | -- | 0 | |
c) Corrosion of reinforcement? | NO Problem | -- | -- | 0 | |
d) Poor concrete? | NO Problem | -- | -- | 0 | |
D- MASONRY WALLS | |||||
a) Cracking? | NO Problem | -- | -- | 0 | |
b) Bulging? | NO Problem | -- | -- | 0 | |
c) Poor pointing? | NO Problem | -- | -- | 0 | |
d) Deterioration of bricks or stones? | NO Problem | -- | -- | 0 | |
E- EMBANKMENTS AND FILL IN FRONT OF ABUTMENT | |||||
a) Scour at base of slopes? | NO Problem | -- | -- | 0 | |
b) Slippage of fill? | NO Problem | -- | -- | 0 | |
c) Erosion of fill? | NO Problem | -- | -- | 0 | |
d) Cracking of road or embankment edge? | NO Problem | -- | -- | 0 | |
e) Piping failure of fill? | NO Problem | -- | -- | 0 | |
9 | Embankments Component Weightage 10 | ||||
A- STONE PITCHING SLOPE PROTECTION | |||||
a) Cracking? | Not Applicable | -- | -- | -- | |
b) Poor pointing? | Not Applicable | -- | -- | -- | |
c) Scour or erosion at edge? | Not Applicable | -- | -- | -- | |
d) Pieces broken off? | Not Applicable | -- | -- | -- | |
e) Piping failure of fill? | Not Applicable | -- | -- | -- | |
B- SLOPE PROTECTION WITH CRATES | |||||
a) Not much movement of crates? | Not Applicable | -- | -- | -- | |
b) Damage to crates or ties? | Not Applicable | -- | -- | -- | |
C- PITCHING SLOPE PROTECTION WITH CONCRETE BLOCKS | |||||
a) Slope getting washed out? | Not Applicable | -- | -- | -- | |
b) Settlement? | Not Applicable | -- | -- | -- | |
10 | RIVER BED Component Weightage 10 | ||||
A- BED PROTECTION AND APRONS | |||||
a) Large holes in the river bed? | Not Applicable | -- | -- | -- | |
b) Loss of material | Not Applicable | -- | -- | -- | |
c) Crates broken away from pier or abutment? | Not Applicable | -- | -- | -- | |
d) Damage to wires or ties? | Not Applicable | -- | -- | -- | |
B- STONE PITCHING OR CONCRETE BED PROTECTION AND APRONS | |||||
a) Scour at edge? | Not Applicable | -- | -- | -- | |
b) Cracking? | Not Applicable | -- | -- | -- | |
c) Spalling or stones missing? | Not Applicable | -- | -- | -- | |
d) Erosion of surface? | Not Applicable | -- | -- | -- | |
e) Corrosion of reinforcement? | Not Applicable | -- | -- | -- |
End of Report