ID :960
Pedestrain Bridge Over Bhagirathi River near Koteshwar
on Chainage 0.037 of road unknown
In District Tehri Under CD Narendnagar Division
Critical Report on Bridge Condition
Form Filled By Mohd. Arif Khan [61006175]
Inspection Team
Detail Report
# | Parameter | Problem ? | How Bad? | How Much? | |
---|---|---|---|---|---|
1 | ROAD APPROCHES AND DECK Component Weightage 10 | ||||
A- ROAD SURFACE NEAR BRIDGE | |||||
a) Bumpy road surface near bridge? | Not Applicable | -- | -- | -- | |
B- DRAINAGE | |||||
a) Badly built road drainage near bridge? | Not Applicable | -- | -- | -- | |
b) Blocked or damaged road drains? | Not Applicable | -- | -- | -- | |
c) Water on the deck? | Not Applicable | -- | -- | -- | |
d) Blocked or damaged deck drains? | Not Applicable | -- | -- | -- | |
C- WEARING COAT | |||||
STEEL WEARING COURSE | |||||
a) Fixings loose or damaged? | NO Problem | -- | -- | 0 | |
b) Bonds in panels? | NO Problem | -- | -- | 0 | |
c) Corrosion? | Yes | Bad | Some Qty | 5 | |
D- KERBS & FOOTPATHS | |||||
a) Loose railing fixtures? | Not Applicable | -- | -- | -- | |
a) Damaged or loose kerbs? | Not Applicable | -- | -- | -- | |
2 | PARAPETS, RAILINGS AND CRASH BARRIERS Component Weightage 10 | ||||
a) Impact damaged? | Not Applicable | -- | -- | -- | |
b) Loose or damaged fixings? | Yes | Bad | Not Much Qty | 4 | |
c) Loose base of posts? | Yes | Bad | Not Much Qty | 4 | |
d) Damaged coatirig or paint on steel surface? | Yes | Bad | Much Qty | 6 | |
e) Corrosion on steel surface? | Yes | Bad | Some Qty | 5 | |
f) Cracking on Masonary Parapets? | Yes | Not So Bad | Not Much Qty | 1 | |
g) Movement or bending of parapet? | Not Applicable | -- | -- | -- | |
h) Poor pointing/ Plaster on parapet? | Yes | Not So Bad | Not Much Qty | 1 | |
i) Deterioration of bricks or stones? | Yes | Not So Bad | Not Much Qty | 1 | |
3 | EXPANSION JOINT AT ABUTMENTS & PIERS Component Weightage 10 | ||||
a) Damage to concrete of deck end or dirt wall near joint? | Yes | Bad | Not Much Qty | 4 | |
b) Debris or vegetation in joint? | Yes | Not So Bad | Much Qty | 3 | |
c) Loose or damaged fixtures? | Yes | Not So Bad | Some Qty | 2 | |
d) Damage or corrosion to metal parts? | Yes | Bad | Much Qty | 6 | |
e) Damage to rubber waterseals? | Not Applicable | -- | -- | -- | |
4 | RIVER Component Weightage 10 | ||||
A- BLOCKAGES IN WATERWAY | |||||
a) Debris against piers or abutments? | NO Problem | -- | -- | 0 | |
b) Remains of old bridge under or upstream of the bridge? | Not Applicable | -- | -- | -- | |
c) Fencing or buildings under bridge? | Not Applicable | -- | -- | -- | |
d) Trees or bushes.growing under bridge? | NO Problem | -- | -- | 0 | |
B- CHANGE IN RIVER COURSE | |||||
a) River changing path upstream of bridge? | NO Problem | -- | -- | 0 | |
b) New islands forming upstream of bridge? | NO Problem | -- | -- | 0 | |
C- RIVER TRAINING WORKS | |||||
a) River attack beyond the upstream end of river training works? | Not Applicable | -- | -- | -- | |
b) Damage to walls? | Not Applicable | -- | -- | -- | |
c) Loss of pitching? | Not Applicable | -- | -- | -- | |
d) Damage to crates, timber, fencing, etc.? | Not Applicable | -- | -- | -- | |
e) Damage to trees? | Not Applicable | -- | -- | -- | |
5 | SUPERSTRUCTURE Component Weightage 60 | ||||
CONCRETE | |||||
General | |||||
a) Impact damage to girders, trusses or bracings? | NO Problem | -- | -- | 0 | |
b) Debris or vegetation on beams, girders, trusses bracings or joints? | NO Problem | -- | -- | 0 | |
c) Water coming through the deck? | NO Problem | -- | -- | 0 | |
d) Water from the deck drainage flowing on to girders, trusses, beams or bracings? | NO Problem | -- | -- | 0 | |
e) Not enough vertical & horizontal clearances? | NO Problem | -- | -- | 0 | |
CONCRETE BEAMS | |||||
a) Cracking? | NO Problem | -- | -- | 0 | |
b) Spalling? | NO Problem | -- | -- | 0 | |
c) Corrosion of reinforcement? | NO Problem | -- | -- | 0 | |
d) Poor concrete? | NO Problem | -- | -- | 0 | |
CONCRETE UNDERSIDE OF DECK | |||||
a) Cracking? | NO Problem | -- | -- | 0 | |
b) Spalling? | NO Problem | -- | -- | 0 | |
c) Reinforcement corrosion? | NO Problem | -- | -- | 0 | |
d) Poor concrete? | NO Problem | -- | -- | 0 | |
e) Less cover to reinforcement? | NO Problem | -- | -- | 0 | |
6 | BEARINGS Component Weightage 10 | ||||
METAL BEARINGS | |||||
a) Debris or vegetation around bearings? | Yes | Not So Bad | Some Qty | 2 | |
b) Bad drainage? | Yes | Not So Bad | Some Qty | 2 | |
c) Not enough room for the bridge span to move? | NO Problem | -- | -- | 0 | |
d) Bearing not seated properly? | NO Problem | -- | -- | 0 | |
e) Bridge span not seated properly on bearing? | NO Problem | -- | -- | 0 | |
f) Damaged bedding mortar? | Yes | Not So Bad | Some Qty | 2 | |
g) Damaged or loose earthquake restraints? | Not Applicable | -- | -- | -- | |
METAL BEARINGS | |||||
a) Parts not properly seated? | NO Problem | -- | -- | 0 | |
b) Parts not free to move? | NO Problem | -- | -- | 0 | |
c) Problem with the lubrication system? | Yes | Bad | Some Qty | 5 | |
d) Sliding surfaces damaged? | NO Problem | -- | -- | 0 | |
e) Cracks or bends in metal parts/ Bearing? | NO Problem | -- | -- | 0 | |
f) Corrosion of metal parts? | Yes | Bad | Some Qty | 5 | |
7 | Right Side ABUTMENT, WING WALLS & RETAINING WALLS Component Weightage 10 | ||||
A- GENERAL | |||||
a) Erosion or scour at abutment? | NO Problem | -- | -- | 0 | |
b) Damage to foundation? | NO Problem | -- | -- | 0 | |
c) Movement of abutment? | NO Problem | -- | -- | 0 | |
d) Debris against abutment? | NO Problem | -- | -- | 0 | |
e) Vegetation growing on-or in abutment? | NO Problem | -- | -- | 0 | |
f) Scour near to retaining walls? | NO Problem | -- | -- | 0 | |
g) Movement of retaining walls? | NO Problem | -- | -- | 0 | |
h) Water leaking down through the expansion joint? | NO Problem | -- | -- | 0 | |
B- DRAINAGE SYSTEM | |||||
a) Not enough weepholes? | Not Applicable | -- | -- | -- | |
b) Weepholes not working? | Yes | Not So Bad | Some Qty | 2 | |
c) Water leaking through the abutment? | Yes | Not So Bad | Not Much Qty | 1 | |
C- CONCRETE WALLS | |||||
a) Cracking? | NO Problem | -- | -- | 0 | |
b) Spalling? | NO Problem | -- | -- | 0 | |
c) Corrosion of reinforcement? | Yes | Bad | Not Much Qty | 4 | |
d) Poor concrete? | NO Problem | -- | -- | 0 | |
D- MASONRY WALLS | |||||
a) Cracking? | NO Problem | -- | -- | 0 | |
b) Bulging? | NO Problem | -- | -- | 0 | |
c) Poor pointing? | NO Problem | -- | -- | 0 | |
d) Deterioration of bricks or stones? | Yes | Bad | Not Much Qty | 4 | |
E- EMBANKMENTS AND FILL IN FRONT OF ABUTMENT | |||||
a) Scour at base of slopes? | NO Problem | -- | -- | 0 | |
b) Slippage of fill? | NO Problem | -- | -- | 0 | |
c) Erosion of fill? | NO Problem | -- | -- | 0 | |
d) Cracking of road or embankment edge? | NO Problem | -- | -- | 0 | |
e) Piping failure of fill? | NO Problem | -- | -- | 0 | |
8 | Left Side ABUTMENT, WING WALLS & RETAINING WALLS Component Weightage 10 | ||||
A- GENERAL | |||||
a) Erosion or scour at abutment? | NO Problem | -- | -- | 0 | |
b) Damage to foundation? | NO Problem | -- | -- | 0 | |
c) Movement of abutment? | NO Problem | -- | -- | 0 | |
d) Debris against abutment? | NO Problem | -- | -- | 0 | |
e) Vegetation growing on-or in abutment? | Yes | Bad | Not Much Qty | 4 | |
f) Scour near to retaining walls? | NO Problem | -- | -- | 0 | |
g) Movement of retaining walls? | NO Problem | -- | -- | 0 | |
h) Water leaking down through the expansion joint? | NO Problem | -- | -- | 0 | |
B- DRAINAGE SYSTEM | |||||
a) Not enough weepholes? | Not Applicable | -- | -- | -- | |
b) Weepholes not working? | Yes | Bad | Not Much Qty | 4 | |
c) Water leaking through the abutment? | Yes | Bad | Not Much Qty | 4 | |
C- CONCRETE WALLS | |||||
a) Cracking? | NO Problem | -- | -- | 0 | |
b) Spalling? | NO Problem | -- | -- | 0 | |
c) Corrosion of reinforcement? | NO Problem | -- | -- | 0 | |
d) Poor concrete? | NO Problem | -- | -- | 0 | |
D- MASONRY WALLS | |||||
a) Cracking? | NO Problem | -- | -- | 0 | |
b) Bulging? | NO Problem | -- | -- | 0 | |
c) Poor pointing? | NO Problem | -- | -- | 0 | |
d) Deterioration of bricks or stones? | NO Problem | -- | -- | 0 | |
E- EMBANKMENTS AND FILL IN FRONT OF ABUTMENT | |||||
a) Scour at base of slopes? | NO Problem | -- | -- | 0 | |
b) Slippage of fill? | NO Problem | -- | -- | 0 | |
c) Erosion of fill? | NO Problem | -- | -- | 0 | |
d) Cracking of road or embankment edge? | NO Problem | -- | -- | 0 | |
e) Piping failure of fill? | NO Problem | -- | -- | 0 | |
9 | Embankments Component Weightage 10 | ||||
A- STONE PITCHING SLOPE PROTECTION | |||||
a) Cracking? | Not Applicable | -- | -- | -- | |
b) Poor pointing? | Not Applicable | -- | -- | -- | |
c) Scour or erosion at edge? | Not Applicable | -- | -- | -- | |
d) Pieces broken off? | Not Applicable | -- | -- | -- | |
e) Piping failure of fill? | Not Applicable | -- | -- | -- | |
B- SLOPE PROTECTION WITH CRATES | |||||
a) Not much movement of crates? | Not Applicable | -- | -- | -- | |
b) Damage to crates or ties? | Not Applicable | -- | -- | -- | |
C- PITCHING SLOPE PROTECTION WITH CONCRETE BLOCKS | |||||
a) Slope getting washed out? | Not Applicable | -- | -- | -- | |
b) Settlement? | NO Problem | -- | -- | 0 | |
10 | RIVER BED Component Weightage 10 | ||||
A- BED PROTECTION AND APRONS | |||||
a) Large holes in the river bed? | Not Applicable | -- | -- | -- | |
b) Loss of material | NO Problem | -- | -- | 0 | |
c) Crates broken away from pier or abutment? | Not Applicable | -- | -- | -- | |
d) Damage to wires or ties? | Not Applicable | -- | -- | -- | |
B- STONE PITCHING OR CONCRETE BED PROTECTION AND APRONS | |||||
a) Scour at edge? | Not Applicable | -- | -- | -- | |
b) Cracking? | Not Applicable | -- | -- | -- | |
c) Spalling or stones missing? | Not Applicable | -- | -- | -- | |
d) Erosion of surface? | Not Applicable | -- | -- | -- | |
e) Corrosion of reinforcement? | Yes | Bad | Not Much Qty | 4 |
End of Report