Bridge (ID- 1062 ) Inventory Report

kauli knyal bridge On Chainage 0.975 of Link road from Km 12 of Jauljibi Munsyari motor road to Koli Kanyal

Data finalized On 21 Nov 2022

By neeraj kumar

Last Rated On 16 Jun 2024

Rating 0.12%

Categorized As

XXXXX on XX-XX-XXXX

In District : Pithoragarh Under Division : CD Askote

General

Bridge Type : Motor Bridge High Level
Structure No : 1/1
Feature Intersected : Gori River
Name of Bridge : kauli knyal bridge
Nearest Town : Kauli
Latitude (Northing) : 29.84152500
Longitude (Easting) : 80.35362600
Construction Year : 2002
Inventory Year : 2021

Geometric

Overall length (in meter) : 60.00
Total No of Span : 1
Maximuam Span (in meter) : 60.00
Span Arragment : 1x20m+1x20m+1x20m
No of Lane : 1.000
Overall Width (m) : 5.000
Carriageway Width (m) : 4.250
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 6.500
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 0.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : Truss
Superstructure Material : Steel
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Steel rolled section
Bearing type : Roller & Rocker

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : Plum concrete,Stone masonary
Bank Protection Right Side of Up-stream : Plum concrete,Stone masonary
Bank Protection Left Side of Down-stream : Plum concrete,Stone masonary
Bank Protection Right Side of Down-stream : Plum concrete,Stone masonary
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided