Bridge (ID- 1118 ) Inventory Report

Karai Pul On Chainage 36.775 of BhatraujKhan Ganai Chaukhutia state highway

Data finalized On 31 Oct 2022

By Er. Khajan singh rawat

Last Rated On 17 Jun 2024

Rating 0.00%

Categorized As

XXXXX on XX-XX-XXXX

In District : Almora Under Division : CD Ranikhet

General

Bridge Type : Motor Bridge High Level
Structure No : 37/2
Feature Intersected : Binoli Gadhera
Name of Bridge : Karai Pul
Nearest Town : Kaidar
Latitude (Northing) : 29.77700278
Longitude (Easting) : 79.23744722
Construction Year : 1960
Inventory Year : 2021

Geometric

Overall length (in meter) : 19.70
Total No of Span : 1
Maximuam Span (in meter) : 19.70
Span Arragment : 1x19.70
No of Lane : 1.000
Overall Width (m) : 5.000
Carriageway Width (m) : 2.300
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 6.500
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 840.000
OFL Ordinary Flood Level : 838.000
LWL Low Water Level : 837.000
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Masonry
Wearing Coat Type : Cement Concrete
Expension Joint Type : Other
Railing/Crash Barrier type : Pre-cast concrete
Bearing type : Not Provided

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Raft
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : Masonory Wing Wall
Bank Protection Right Side of Up-stream : Masonory Wing Wall
Bank Protection Left Side of Down-stream : Masonory Wing Wall
Bank Protection Right Side of Down-stream : Masonory Wing Wall
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided