Bridge (ID- 1186 ) Inventory Report

Rampur gadera bridge On Chainage 70.245 of Rudarprayag Gorikund National Highway

Data finalized On 03 Feb 2024

By Er Buddhiram Bhatt

Last Rated On 18 Nov 2023

Rating 1.78%

Categorized As

XXXXX on XX-XX-XXXX

In District : Rudraprayag Under Division : NH Rudraprayag

General

Bridge Type : Motor Bridge High Level
Structure No : 25
Feature Intersected : Rampur gadera
Name of Bridge : Rampur gadera bridge
Nearest Town : Rampur
Latitude (Northing) : 30.61205400
Longitude (Easting) : 79.01264000
Construction Year : 2012
Inventory Year : 2024

Geometric

Overall length (in meter) : 38.00
Total No of Span : 1
Maximuam Span (in meter) : 38.00
Span Arragment : 1*38
No of Lane : 2.000
Overall Width (m) : 12.000
Carriageway Width (m) : 7.500
RS Footpath Width (m) : 1.500
LS Footpath Width (m) : 1.500
Approch Width i/c Shoulders (m) : 11.800
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 0.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : Box girder
Superstructure Material : Pre-stressed concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Steel rolled section
Bearing type : POT PIN

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : RCC buttressed type
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : Protected by CC Block.
Floor Protection on Down-stream : Protected by CC Block.
Tratment for Corrosion Protection (if any) : no special treatment provided