Data finalized On 05 Aug 2022
By Govind singh Mahara
Last Rated On 25 May 2024
Rating 1.86%
Categorized As
XXXXX on XX-XX-XXXX
In District : Bageshwar Under Division : CD Kapkot
General
Bridge Type :
Motor Bridge High Level
Structure No :
1/1
Feature Intersected :
Saryu River
Name of Bridge :
84.00 meter Span Steel Girder Moter Bridge (1.50 Lane)
Nearest Town :
Bharari
Latitude (Northing) :
29.97298900
Longitude (Easting) :
79.90919400
Construction Year :
2020
Inventory Year :
2020
Geometric
Overall length (in meter) :
84.00
Total No of Span :
1
Maximuam Span (in meter) :
84.00
Span Arragment :
1x84.00
No of Lane :
1.500
Overall Width (m) :
5.500
Carriageway Width (m) :
5.500
RS Footpath Width (m) :
0.000
LS Footpath Width (m) :
0.000
Approch Width i/c Shoulders (m) :
7.000
Gradient (%age) :
4
Skew Angle (degree) :
0.00
Radius of Curve in Plan (if Any) :
0.00
Design Data
HFL Highest Flood Level :
1107.500
OFL Ordinary Flood Level :
1102.500
LWL Low Water Level :
1100.000
Design Velocity (m/Sec) :
8.00
Design Discharge (Cumecs) :
3200.00
Soffit Level at Centre :
1112.300
Road Level at Centre :
1114.150
Design Scour Level at Pier :
1.500
Design Scour Level at Abutments :
6.500
Exposure Condition :
Severe
Seismic Importance factor :
1.2
Design Loading :
Class A
Load Rating :
Class A
Super-Structure
Superstructure Type :
Truss
Superstructure Material :
Steel
Wearing Coat Type :
Cement Concrete
Expension Joint Type :
Single Strip/Box Seal Joint
Railing/Crash Barrier type :
Steel rolled section
Bearing type :
POT PIN
Sub-Structure
Founding Strata :
Rocky
Abutment Foundation Type :
Open
Pier Foundation Type :
NA
No of Piers :
0
Abutment Type :
RCC Box type
Pier Type :
NA
Protection Work
Bank Protection Left Side of Up-stream :
Plum Concrete Block
Bank Protection Right Side of Up-stream :
no protection work provided
Bank Protection Left Side of Down-stream :
Plum Concrete Block
Bank Protection Right Side of Down-stream :
no protection work provided
Floor Protection on Up-stream :
no protection work provided
Floor Protection on Down-stream :
no protection work provided
Tratment for Corrosion Protection (if any) :
Steel Paint