Bridge (ID- 147 ) Inventory Report

Sattowali Ghati Bridge On Chainage 0.800 of New Patel Nagar Iron's Bridge to Sattowala Ghati Aproach Road

Data finalized On 20 Feb 2024

By Er. Bharat Rawat

Last Rated On 13 May 2024

Rating 0.45%

Categorized As

XXXXX on XX-XX-XXXX

In District : Dehradun Under Division : CD Dehradun

General

Bridge Type : Motor Bridge High Level
Structure No : 1/1
Feature Intersected : Bindal river
Name of Bridge : Sattowali Ghati Bridge
Nearest Town : Gandhi Gram
Latitude (Northing) : 30.31426700
Longitude (Easting) : 78.01534700
Construction Year : 2003
Inventory Year : 2020

Geometric

Overall length (in meter) : 27.00
Total No of Span : 8
Maximuam Span (in meter) : 27.00
Span Arragment : 8x3
No of Lane : 1.500
Overall Width (m) : 6.000
Carriageway Width (m) : 5.000
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 6.000
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : Box girder
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Not Provided
Railing/Crash Barrier type : Steel rolled section
Bearing type : Not Provided

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : Well
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : RCC Solid

Protection Work

Bank Protection Left Side of Up-stream : R.R. Masonry
Bank Protection Right Side of Up-stream : R.R. Masonry
Bank Protection Left Side of Down-stream : R.R. Masonry
Bank Protection Right Side of Down-stream : R.R. Masonry
Floor Protection on Up-stream : Cement Concrete Floor
Floor Protection on Down-stream : Cement Concrete Floor
Tratment for Corrosion Protection (if any) : Not required (RCC Box Culvert)