Bridge (ID- 150 ) Inventory Report

MANDAKINI RIVER BRIDGE On Chainage 3.682 of Rudarprayag Gorikund National Highway

Data finalized On 02 Feb 2024

By Er. Vishwas saini

Last Rated On 15 Jul 2024

Rating 0.09%

Categorized As

XXXXX on XX-XX-XXXX

In District : Rudraprayag Under Division : NH Rudraprayag

General

Bridge Type : Motor Bridge High Level
Structure No : 2
Feature Intersected : MANDAKINI
Name of Bridge : MANDAKINI RIVER BRIDGE
Nearest Town : RUDRAPRAYAG
Latitude (Northing) : 30.29589000
Longitude (Easting) : 78.97720200
Construction Year : 2012
Inventory Year : 2024

Geometric

Overall length (in meter) : 95.00
Total No of Span : 3
Maximuam Span (in meter) : 65.00
Span Arragment : 1*15+1*65+1*15
No of Lane : 2.000
Overall Width (m) : 12.000
Carriageway Width (m) : 7.800
RS Footpath Width (m) : 1.500
LS Footpath Width (m) : 1.500
Approch Width i/c Shoulders (m) : 12.000
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 0.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : Box girder
Superstructure Material : Composite
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Tubular steel
Bearing type : POT PIN

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Raft
Pier Foundation Type : Raft
No of Piers : 2
Abutment Type : RCC Box type
Pier Type : RCC Solid

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided