Bridge (ID- 1583 ) Inventory Report

स्वतंत्रता संग्राम सैनानी ”वृक्ष मानव“ श्री विश्वेश्वर दत्त सकलानी मोटर मार्ग कि0मी0-9 है0मी0 0-2 On Chainage 8.050 of Late tree man Shri Vishveshwar Dutt Saklani motor road (Raipur Kaddukhal state highway)

Data Yet Not Finalized

Last Rated On 07 May 2024

Rating 17.84%

Categorized As

XXXXX on XX-XX-XXXX

In District : Tehri Under Division : TD Thathyd

General

Bridge Type : Motor Bridge High Level
Structure No : 9/1
Feature Intersected : baadal river
Name of Bridge : स्वतंत्रता संग्राम सैनानी ”वृक्ष मानव“ श्री विश्वेश्वर दत्त सकलानी मोटर मार्ग कि0मी0-9 है0मी0 0-2
Nearest Town : sirki village
Latitude (Northing) : 30.35212500
Longitude (Easting) : 78.13997500
Construction Year : 1978
Inventory Year : 2021

Geometric

Overall length (in meter) : 36.00
Total No of Span : 1
Maximuam Span (in meter) : 38.30
Span Arragment : 1x36
No of Lane : 1.000
Overall Width (m) : 4.850
Carriageway Width (m) : 4.200
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 6.300
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) : 0.00
Design Discharge (Cumecs) : 0.00
Soffit Level at Centre : 7.200
Road Level at Centre : 7.400
Design Scour Level at Pier : 0.000
Design Scour Level at Abutments : 0.000
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : Truss
Superstructure Material : Steel
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Steel rolled section
Bearing type : Elastomeric

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : protected
Bank Protection Left Side of Down-stream : guide wall
Bank Protection Right Side of Down-stream : canal protected
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : Required in soffit