Bridge (ID- 161 ) Inventory Report

Kund bridge On Chainage 34.600 of Rudarprayag Gorikund National Highway (NH)

Data Yet Not Finalized

Last Rated On 23 Jun 2025

Rating 24.50%

Categorized As

XXXXX on XX-XX-XXXX

In District : Rudraprayag Under Division : NH Div Rudraprayag

General

Bridge Type : Motor Bridge High Level
Structure No : 9
Feature Intersected : Mandakini
Name of Bridge : Kund bridge
Nearest Town : Kund
Latitude (Northing) : 30.50378900
Longitude (Easting) : 79.08743528
Construction Year : 2025
Inventory Year : 2026
Work Code(s) : --

Geometric

Overall length (in meter) : 70.00
Total No of Span : 1
Maximuam Span (in meter) : 70.00
Span Arragment : 1*49.80
No of Lane : 1.000
Overall Width (m) : 5.150
Carriageway Width (m) : 4.400
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 4.400
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Very Severe
Seismic Importance factor : 0.0
Design Loading : Class A
Load Rating : Class B

Super-Structure

Superstructure Type : Truss
Superstructure Material : Steel
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Tubular steel
Bearing type : Elastomeric

Sub-Structure

Founding Strata : Sandy
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no protection work provided