Bridge (ID- 1613 ) Inventory Report

Chauras Bridge

Data finalized On 04 Oct 2022

By Ajeet Singh

Last Rated On 04 May 2024

Rating 0.00%

Categorized As

XXXXX on XX-XX-XXXX

In District : Pauri Under Division : CD Srinagar

General

Bridge Type : Motor Bridge High Level
Structure No : 1/1
Feature Intersected : Akaknanda River
Name of Bridge : Chauras Bridge
Nearest Town : Srinagar Garhwal
Latitude (Northing) : 30.21898000
Longitude (Easting) : 78.80588000
Construction Year : 2018
Inventory Year : 2021

Geometric

Overall length (in meter) : 190.00
Total No of Span : 4
Maximuam Span (in meter) : 80.00
Span Arragment : 40+80+30+40
No of Lane : 2.000
Overall Width (m) : 11.500
Carriageway Width (m) : 7.500
RS Footpath Width (m) : 2.000
LS Footpath Width (m) : 2.000
Approch Width i/c Shoulders (m) : 14.000
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 547.490
OFL Ordinary Flood Level : 543.000
LWL Low Water Level : 541.000
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 0.0
Design Loading : Class AA
Load Rating : Class A

Super-Structure

Superstructure Type : Truss
Superstructure Material : Steel
Wearing Coat Type : Mastic asphalt
Expension Joint Type : Modular Strip/Box Seal Joints
Railing/Crash Barrier type : Cast-in-situ concrete
Bearing type : other

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : Well
No of Piers : 3
Abutment Type : RCC counterfort type
Pier Type : RCC Solid

Protection Work

Bank Protection Left Side of Up-stream : No protection provided
Bank Protection Right Side of Up-stream : Protected with RCC Wall
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided