Bridge (ID- 1655 ) Inventory Report

ISBT Flyover

Data finalized On 12 Oct 2021

By Lalit Mohan JE

Last Rated On 20 Jun 2024

Rating 2.09%

Categorized As

XXXXX on XX-XX-XXXX

In District : Dehradun Under Division : NH Dehradun

General

Bridge Type : Fly Over
Structure No : 14 (12 Pier + 2 Abutment)
Feature Intersected : ISBT junction
Name of Bridge : ISBT Flyover
Nearest Town : Dehradun
Latitude (Northing) : 30.17191200
Longitude (Easting) : 77.59482000
Construction Year : 2016
Inventory Year : 2021

Geometric

Overall length (in meter) : 409.40
Total No of Span : 13
Maximuam Span (in meter) : 32.20
Span Arragment : 11x32.2+1x28.2+1x27
No of Lane : 2.000
Overall Width (m) : 15.600
Carriageway Width (m) : 14.000
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 14.000
Gradient (%age) : 3
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Bituminous Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Pre-cast concrete
Bearing type : POT PIN

Sub-Structure

Founding Strata : Hard clayey
Abutment Foundation Type : Pile
Pier Foundation Type : Pile
No of Piers : 13
Abutment Type : RCC buttressed type
Pier Type : RCC Solid

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided