Bridge (ID- 1723 ) Inventory Report

54.80 Mter Span Steel Girder Motor Bridge at Chaura On Chainage 1.500 of Approach road upto Chaura Village

Data finalized On 06 Aug 2022

By Jagdish Papney

Last Rated On 24 May 2024

Rating 2.76%

Categorized As

XXXXX on XX-XX-XXXX

In District : Bageshwar Under Division : CD Kapkot

General

Bridge Type : Motor Bridge High Level
Structure No : 1/1
Feature Intersected : Pungar River
Name of Bridge : 54.80 Mter Span Steel Girder Motor Bridge at Chaura
Nearest Town : Chaura
Latitude (Northing) : 29.87412300
Longitude (Easting) : 79.85821500
Construction Year : 1998
Inventory Year : 2022

Geometric

Overall length (in meter) : 54.80
Total No of Span : 1
Maximuam Span (in meter) : 54.80
Span Arragment : 1x54.80
No of Lane : 1.000
Overall Width (m) : 4.250
Carriageway Width (m) : 4.250
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 6.000
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 1007.500
OFL Ordinary Flood Level : 1002.000
LWL Low Water Level : 1000.000
Design Velocity (m/Sec) : 6.00
Design Discharge (Cumecs) : 2500.00
Soffit Level at Centre : 1008.000
Road Level at Centre : 1009.000
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : Truss
Superstructure Material : Steel
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Steel rolled section
Bearing type : Roller & Rocker

Sub-Structure

Founding Strata : Bouldery
Abutment Foundation Type : Raft
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : Plum Concrete Block
Bank Protection Right Side of Up-stream : Plum Concrete Block
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided