Data finalized On 10 Jun 2022
By Er. Sachin Kumar
Last Rated On 14 Jun 2024
Rating 0.00%
Categorized As
XXXXX on XX-XX-XXXX
In District : Udham Singh Nagar Under Division : PD Rudrapur
General
Bridge Type :
Motor Bridge High Level
Structure No :
2/3
Feature Intersected :
Nala
Name of Bridge :
Khurpyia Bridge
Nearest Town :
Khurpiya
Latitude (Northing) :
28.96613056
Longitude (Easting) :
79.48659722
Construction Year :
Inventory Year :
2021
Geometric
Overall length (in meter) :
11.11
Total No of Span :
1
Maximuam Span (in meter) :
11.10
Span Arragment :
1*11.10
No of Lane :
1.000
Overall Width (m) :
7.000
Carriageway Width (m) :
5.500
RS Footpath Width (m) :
0.750
LS Footpath Width (m) :
0.750
Approch Width i/c Shoulders (m) :
7.000
Gradient (%age) :
0
Skew Angle (degree) :
0.00
Radius of Curve in Plan (if Any) :
0.00
Design Data
HFL Highest Flood Level :
120.000
OFL Ordinary Flood Level :
110.000
LWL Low Water Level :
108.000
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition :
Moderate
Seismic Importance factor :
0.0
Design Loading :
Class B
Load Rating :
Class B
Super-Structure
Superstructure Type :
T-beam and slab
Superstructure Material :
Reinforced concrete
Wearing Coat Type :
Cement Concrete
Expension Joint Type :
Other
Railing/Crash Barrier type :
Cast-in-situ concrete
Bearing type :
Not Provided
Sub-Structure
Founding Strata :
Sandy
Abutment Foundation Type :
other
Pier Foundation Type :
other
No of Piers :
0
Abutment Type :
RCC Box type
Pier Type :
RCC Solid
Protection Work
Bank Protection Left Side of Up-stream :
no protection work provided
Bank Protection Right Side of Up-stream :
no protection work provided
Bank Protection Left Side of Down-stream :
no protection work provided
Bank Protection Right Side of Down-stream :
no protection work provided
Floor Protection on Up-stream :
no protection work provided
Floor Protection on Down-stream :
no protection work provided
Tratment for Corrosion Protection (if any) :
no special treatment provided