Data finalized On 26 Nov 2022
By Er. Mahendra Singh Dawan
Last Rated On 17 May 2024
Rating 1.45%
Categorized As
XXXXX on XX-XX-XXXX
In District : Pauri Under Division : PD Pauri
General
Bridge Type :
Motor Bridge High Level
Structure No :
81/1
Feature Intersected :
Thangarh Gadera
Name of Bridge :
RCC motor Bridge
Nearest Town :
Chopra
Latitude (Northing) :
30.02142000
Longitude (Easting) :
78.63487000
Construction Year :
2010
Inventory Year :
2022
Geometric
Overall length (in meter) :
12.50
Total No of Span :
1
Maximuam Span (in meter) :
12.50
Span Arragment :
1x12.50
No of Lane :
1.000
Overall Width (m) :
7.500
Carriageway Width (m) :
6.000
RS Footpath Width (m) :
0.000
LS Footpath Width (m) :
0.000
Approch Width i/c Shoulders (m) :
7.500
Gradient (%age) :
0
Skew Angle (degree) :
0.00
Radius of Curve in Plan (if Any) :
0.00
Design Data
HFL Highest Flood Level :
559.500
OFL Ordinary Flood Level :
556.000
LWL Low Water Level :
553.500
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
560.550
Road Level at Centre :
562.000
Design Scour Level at Pier :
Design Scour Level at Abutments :
552.000
Exposure Condition :
Moderate
Seismic Importance factor :
1.0
Design Loading :
Class B
Load Rating :
Class B
Super-Structure
Superstructure Type :
Arch
Superstructure Material :
Reinforced concrete
Wearing Coat Type :
Bituminous Concrete
Expension Joint Type :
Not Provided
Railing/Crash Barrier type :
other
Bearing type :
Not Provided
Sub-Structure
Founding Strata :
Rocky
Abutment Foundation Type :
Open
Pier Foundation Type :
NA
No of Piers :
0
Abutment Type :
Stone Masonry
Pier Type :
NA
Protection Work
Bank Protection Left Side of Up-stream :
no protection work provided
Bank Protection Right Side of Up-stream :
no protection work provided
Bank Protection Left Side of Down-stream :
no protection work provided
Bank Protection Right Side of Down-stream :
no protection work provided
Floor Protection on Up-stream :
no protection work provided
Floor Protection on Down-stream :
no protection work provided
Tratment for Corrosion Protection (if any) :
no special treatment provided