Bridge (ID- 1832 ) Inventory Report

68.58m span motor bridge Agnikund On Chainage 0.000 of District Magistrate Office approach motor road

Data finalized On 27 Sep 2022

By Minakshi Pant

Last Rated On 30 Jun 2024

Rating 0.00%

Categorized As

XXXXX on XX-XX-XXXX

In District : Bageshwar Under Division : PD Bageshwar

General

Bridge Type : Motor Bridge High Level
Structure No : 1/1
Feature Intersected : Saryu River
Name of Bridge : 68.58m span motor bridge Agnikund
Nearest Town : Bageshwar
Latitude (Northing) : 29.82829700
Longitude (Easting) : 79.77143900
Construction Year : 2009
Inventory Year : 2022

Geometric

Overall length (in meter) : 68.58
Total No of Span : 1
Maximuam Span (in meter) : 68.58
Span Arragment : 1x68.58m
No of Lane : 1.000
Overall Width (m) : 4.870
Carriageway Width (m) : 4.250
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 6.000
Gradient (%age) : 1
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 859.000
OFL Ordinary Flood Level : 857.000
LWL Low Water Level : 856.000
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 0.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : Truss
Superstructure Material : Steel
Wearing Coat Type : Cement Concrete
Expension Joint Type : Other
Railing/Crash Barrier type : Steel rolled section
Bearing type : Roller & Rocker

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided