Bridge (ID- 198 ) Inventory Report

सुवाखेली -अलमस- भवान नगुण मो0 मार्ग के कि0मी0-15 है0मी0 8-10 On Chainage 15.900 of Suakholi Almas Bhawan Sarot Chapta Nagun state highway

Bridge Declared As Abandoned

On 20 Dec 2023

In District : Tehri Under Division : TD Thathyd

General

Bridge Type : Motor Bridge High Level
Structure No : 1/1
Feature Intersected : almas nala
Name of Bridge : सुवाखेली -अलमस- भवान नगुण मो0 मार्ग के कि0मी0-15 है0मी0 8-10
Nearest Town : bhawan
Latitude (Northing) : 30.47604700
Longitude (Easting) : 78.20066700
Construction Year : 1980
Inventory Year : 2022

Geometric

Overall length (in meter) : 12.00
Total No of Span : 1
Maximuam Span (in meter) : 6.50
Span Arragment : 1x6.00m
No of Lane : 1.000
Overall Width (m) : 4.850
Carriageway Width (m) : 4.250
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 7.500
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : Solid slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Filler
Railing/Crash Barrier type : Cast-in-situ concrete
Bearing type : Not Provided

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : protection work provided
Bank Protection Right Side of Up-stream : protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided