Bridge (ID- 2009 ) Inventory Report

Bailey Bridge at chainage 9.325 of UGT m/r On Chainage 9.325 of Uttarkashi Ghansali Tilwara state highway

Data Yet Not Finalized

Last Rated On 09 Jun 2024

Rating 1.04%

Categorized As

XXXXX on XX-XX-XXXX

In District : Uttarkashi Under Division : PD Bhatwari

General

Bridge Type : Motor Bridge High Level
Structure No : 9/13
Feature Intersected : Sada Gad
Name of Bridge : Bailey Bridge at chainage 9.325 of UGT m/r
Nearest Town : Uttarkashi
Latitude (Northing) : 30.70495700
Longitude (Easting) : 78.47534800
Construction Year : 2021
Inventory Year : 2022

Geometric

Overall length (in meter) : 24.00
Total No of Span : 1
Maximuam Span (in meter) : 24.00
Span Arragment : 24.00
No of Lane : 1.000
Overall Width (m) : 5.700
Carriageway Width (m) : 4.250
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 5.950
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 0.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : Bailey
Superstructure Material : Steel
Wearing Coat Type : Not Provided
Expension Joint Type : Other
Railing/Crash Barrier type : Steel rolled section
Bearing type : other

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : Plum block
Bank Protection Right Side of Up-stream : RR Wing Wall
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : Plum block
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : Plum block
Tratment for Corrosion Protection (if any) : no special treatment provided