Bridge (ID- 2071 ) Inventory Report

Suspension Bridge On Chainage 0.000 of Badkholu Saknikhet Rautela Kanda Bausal motor road (VR)

Bridge Declared As Abandoned

On 03 Jul 2026

In District : Pauri Under Division : PD Pauri

General

Bridge Type : Pedestrain Bridge
Structure No : 1/1
Feature Intersected : Nayar River
Name of Bridge : Suspension Bridge
Nearest Town : Badkholu Near Satpuli
Latitude (Northing) : 29.93759000
Longitude (Easting) : 78.70311000
Construction Year : 1987
Inventory Year : 2022
Work Code(s) : --

Geometric

Overall length (in meter) : 70.00
Total No of Span : 1
Maximuam Span (in meter) : 70.00
Span Arragment : 1x70.000
No of Lane : 1.000
Overall Width (m) : 1.700
Carriageway Width (m) : 1.700
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 1.600
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 552.000
OFL Ordinary Flood Level : 550.000
LWL Low Water Level : 546.000
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre : 554.920
Road Level at Centre : 555.000
Design Scour Level at Pier :
Design Scour Level at Abutments : 540.000
Exposure Condition : Extreme
Seismic Importance factor : 1.0
Design Loading : Footpath Live Load
Load Rating : Footpath Live Load

Super-Structure

Superstructure Type : Suspension
Superstructure Material : Steel
Wearing Coat Type : Other
Expension Joint Type : Not Provided
Railing/Crash Barrier type : Steel rolled section
Bearing type : Not Provided

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided