Bridge (ID- 2084 ) Inventory Report

Bridge on sonali river of 271m span On Chainage 10.735 of Roorkee Landhora Laksar Balawali state highway

Data finalized On 05 Dec 2022

By Balendra singh/Alok Tomar

Last Rated On 24 Oct 2024

Rating 0.66%

Categorized As

XXXXX on XX-XX-XXXX

In District : Haridwar Under Division : CD Laksar

General

Bridge Type : Motor Bridge High Level
Structure No : 02
Feature Intersected : Sonali River
Name of Bridge : Bridge on sonali river of 271m span
Nearest Town : Kuankheda mohammadpur
Latitude (Northing) : 29.46520000
Longitude (Easting) : 77.57370000
Construction Year : 1987
Inventory Year : 2022

Geometric

Overall length (in meter) : 271.00
Total No of Span : 9
Maximuam Span (in meter) : 30.25
Span Arragment : 7*30.25+2*29.36
No of Lane : 2.000
Overall Width (m) : 8.350
Carriageway Width (m) : 7.600
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 9.800
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Tubular steel
Bearing type : Elastomeric

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : Well
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : RCC Solid

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided