Data finalized On 05 Dec 2022
By Er. Alok Tomar. AEEr. Ravindra Kumar, AAE
Last Rated On 25 May 2024
Rating 0.12%
Categorized As
XXXXX on XX-XX-XXXX
In District : Haridwar Under Division : CD Laksar
General
Bridge Type :
Motor Bridge High Level
Structure No :
03
Feature Intersected :
Pathri river major
Name of Bridge :
Box culvert bridge on Pathri row of Laksar raipur motor road
Nearest Town :
Raipur
Latitude (Northing) :
29.45470000
Longitude (Easting) :
78.02420000
Construction Year :
2015
Inventory Year :
2022
Geometric
Overall length (in meter) :
43.00
Total No of Span :
8
Maximuam Span (in meter) :
6.00
Span Arragment :
8*5
No of Lane :
2.000
Overall Width (m) :
8.100
Carriageway Width (m) :
7.100
RS Footpath Width (m) :
0.000
LS Footpath Width (m) :
0.000
Approch Width i/c Shoulders (m) :
6.500
Gradient (%age) :
0
Skew Angle (degree) :
0.00
Radius of Curve in Plan (if Any) :
0.00
Design Data
HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition :
Moderate
Seismic Importance factor :
1.0
Design Loading :
Class A
Load Rating :
Class A
Super-Structure
Superstructure Type :
T-beam and slab
Superstructure Material :
Reinforced concrete
Wearing Coat Type :
Cement Concrete
Expension Joint Type :
Single Strip/Box Seal Joint
Railing/Crash Barrier type :
Tubular steel
Bearing type :
Elastomeric
Sub-Structure
Founding Strata :
Rocky
Abutment Foundation Type :
Open
Pier Foundation Type :
Well
No of Piers :
0
Abutment Type :
Stone Masonry
Pier Type :
RCC Solid
Protection Work
Bank Protection Left Side of Up-stream :
no protection work provided
Bank Protection Right Side of Up-stream :
no protection work provided
Bank Protection Left Side of Down-stream :
no protection work provided
Bank Protection Right Side of Down-stream :
no protection work provided
Floor Protection on Up-stream :
no protection work provided
Floor Protection on Down-stream :
no protection work provided
Tratment for Corrosion Protection (if any) :