Bridge (ID- 2153 ) Inventory Report

Tharkot Bridge On Chainage 3.200 of Acholi Jakh Puran Maldurangri motor road

Data finalized On 04 Jul 2023

By AAE VANDANA THAKUR

Last Rated On 07 Jun 2024

Rating 0.08%

Categorized As

XXXXX on XX-XX-XXXX

In District : Pithoragarh Under Division : PD Pithoragarh

General

Bridge Type : Motor Bridge High Level
Structure No : 14
Feature Intersected : Gharmod Gaad
Name of Bridge : Tharkot Bridge
Nearest Town : Pithoragarh
Latitude (Northing) : 29.56000000
Longitude (Easting) : 80.18360000
Construction Year : 2011
Inventory Year : 2022

Geometric

Overall length (in meter) : 10.00
Total No of Span : 1
Maximuam Span (in meter) : 10.00
Span Arragment : 1 x 10
No of Lane : 1.000
Overall Width (m) : 6.000
Carriageway Width (m) : 5.100
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 0.600
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : NA
Load Rating : NA

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Tubular steel
Bearing type : Not Provided

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : Wing Wall
Bank Protection Right Side of Up-stream : wing wall
Bank Protection Left Side of Down-stream : Wing Wall
Bank Protection Right Side of Down-stream : Wing Wall
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided