Bridge (ID- 2206 ) Inventory Report

ROB Laksar On Chainage 31.000 of Purkazi Laksar Haridwar national highway (NH)

Data finalized On 10 Jan 2024

By Mahabir Lal

Last Rated On 04 Jun 2026

Rating 0.29%

Categorized As

XXXXX on XX-XX-XXXX

In District : Haridwar Under Division : NH Div Dehradun

General

Bridge Type : Road Over Bridge
Structure No : 31/1
Feature Intersected : Laksar
Name of Bridge : ROB Laksar
Nearest Town : Laksar
Latitude (Northing) : 29.74888889
Longitude (Easting) : 78.02388889
Construction Year : 2009
Inventory Year : 2022
Work Code(s) : --

Geometric

Overall length (in meter) : 546.90
Total No of Span : 27
Maximuam Span (in meter) : 25.50
Span Arragment : 12x19.60+3x25.50+12x19.60
No of Lane : 2.000
Overall Width (m) : 7.500
Carriageway Width (m) : 7.500
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 7.500
Gradient (%age) : 3
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Pre-stressed concrete
Wearing Coat Type : Mastic asphalt
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Cast-in-situ concrete
Bearing type : Elastomeric

Sub-Structure

Founding Strata : Sandy
Abutment Foundation Type : Pile
Pier Foundation Type : Pile
No of Piers : 26
Abutment Type : RCC counterfort type
Pier Type : RCC Solid

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided