Bridge (ID- 2365 ) Inventory Report

53.0 M Box cell On Chainage 0.800 of Brick khandja road from the farm of Chaudhary Vedpal on Biharigarh road to bank of Solani river in the village Ganja Majra

Data finalized On 28 Dec 2022

By Arvind Rawat

Last Rated On 03 Dec 2024

Rating 0.00%

Categorized As

XXXXX on XX-XX-XXXX

In District : Haridwar Under Division : PD Haridwar

General

Bridge Type : Motor Bridge High Level
Structure No : 1/1
Feature Intersected : Rajwaha nadi
Name of Bridge : 53.0 M Box cell
Nearest Town : Ganja
Latitude (Northing) : 30.08856960
Longitude (Easting) : 77.83366430
Construction Year : 2019
Inventory Year : 2022

Geometric

Overall length (in meter) : 53.00
Total No of Span : 1
Maximuam Span (in meter) : 53.00
Span Arragment : 4.41x12
No of Lane : 2.000
Overall Width (m) : 7.950
Carriageway Width (m) : 8.400
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 9.000
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Tubular steel
Bearing type : Elastomeric

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : Well
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : RCC Solid

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided