Bridge (ID- 2399 ) Inventory Report

tanakpur askote ditiy paidal marg 6.600 (charma gad steel girder bridge) On Chainage 6.600 of Road from Morgi village to Koda

Data finalized On 23 Nov 2022

By Manish singh kharayat

Last Rated On 15 Jun 2024

Rating 6.94%

Categorized As

XXXXX on XX-XX-XXXX

In District : Pithoragarh Under Division : CD Askote

General

Bridge Type : Pedestrain Bridge
Structure No : 7/1
Feature Intersected : charma gad
Name of Bridge : tanakpur askote ditiy paidal marg 6.600 (charma gad steel girder bridge)
Nearest Town : malan, digra, banderlima
Latitude (Northing) : 29.71590900
Longitude (Easting) : 80.28560000
Construction Year :
Inventory Year : 2022

Geometric

Overall length (in meter) : 24.45
Total No of Span : 1
Maximuam Span (in meter) : 24.00
Span Arragment : 1x24.00
No of Lane : 1.000
Overall Width (m) : 1.800
Carriageway Width (m) : 1.800
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 2.000
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 0.0
Design Loading : NA
Load Rating : NA

Super-Structure

Superstructure Type : Truss
Superstructure Material : Steel
Wearing Coat Type : Not Provided
Expension Joint Type : Filler
Railing/Crash Barrier type : Tubular steel
Bearing type : Roller & Rocker

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : RR masonry wall provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : RR masonry wall provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided