Bridge (ID- 2432 ) Inventory Report

Kirtinagar Bridge On Chainage 323.733 of Delhi Badrinath Mana national highway : .

Data finalized On 04 Jan 2025

By Shashi Negi

Last Rated On 08 Jun 2024

Rating 0.24%

Categorized As

XXXXX on XX-XX-XXXX

In District : Tehri Under Division : NH Srinagar

General

Bridge Type : Motor Bridge High Level
Structure No : 58/55
Feature Intersected : Alaknanda
Name of Bridge : Kirtinagar Bridge
Nearest Town : Kirtinagar
Latitude (Northing) : 30.21369600
Longitude (Easting) : 78.74717600
Construction Year : 1990
Inventory Year : 2022

Geometric

Overall length (in meter) : 124.60
Total No of Span : 3
Maximuam Span (in meter) : 69.00
Span Arragment : 1*30+1*69+1*25.6
No of Lane : 2.000
Overall Width (m) : 10.950
Carriageway Width (m) : 7.550
RS Footpath Width (m) : 1.250
LS Footpath Width (m) : 1.250
Approch Width i/c Shoulders (m) : 12.000
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 0.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Modular Strip/Box Seal Joints
Railing/Crash Barrier type : Cast-in-situ concrete
Bearing type : Elastomeric

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : Well
No of Piers : 2
Abutment Type : Stone Masonry
Pier Type : RCC Solid

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided