Data finalized On 09 Jan 2024
By TANUJA DEV
Last Rated On 15 Jun 2024
Rating 0.58%
Categorized As
XXXXX on XX-XX-XXXX
In District : Champawat Under Division : PD Champawat
General
Bridge Type :
Motor Bridge High Level
Structure No :
1/5
Feature Intersected :
Selagaad
Name of Bridge :
Steel girder bridge in km 18.00 at kakraligate thuligarh motor road
Nearest Town :
TANAKPUR
Latitude (Northing) :
29.15518200
Longitude (Easting) :
80.19112000
Construction Year :
2005
Inventory Year :
2022
Geometric
Overall length (in meter) :
30.00
Total No of Span :
1
Maximuam Span (in meter) :
30.00
Span Arragment :
1x30
No of Lane :
1.000
Overall Width (m) :
4.750
Carriageway Width (m) :
4.050
RS Footpath Width (m) :
0.000
LS Footpath Width (m) :
0.000
Approch Width i/c Shoulders (m) :
5.000
Gradient (%age) :
0
Skew Angle (degree) :
0.00
Radius of Curve in Plan (if Any) :
0.00
Design Data
HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition :
Moderate
Seismic Importance factor :
1.0
Design Loading :
Class B
Load Rating :
Class B
Super-Structure
Superstructure Type :
Truss
Superstructure Material :
Steel
Wearing Coat Type :
Bituminous Concrete
Expension Joint Type :
Modular Strip/Box Seal Joints
Railing/Crash Barrier type :
Tubular steel
Bearing type :
Roller & Rocker
Sub-Structure
Founding Strata :
Bouldery
Abutment Foundation Type :
Raft
Pier Foundation Type :
NA
No of Piers :
0
Abutment Type :
Stone Masonry
Pier Type :
NA
Protection Work
Bank Protection Left Side of Up-stream :
protection work provided
Bank Protection Right Side of Up-stream :
protection work provided
Bank Protection Left Side of Down-stream :
protection work provided
Bank Protection Right Side of Down-stream :
protection work provided
Floor Protection on Up-stream :
No protection work provided
Floor Protection on Down-stream :
No protection work provided
Tratment for Corrosion Protection (if any) :
no special treatment provided