Bridge (ID- 257 ) Inventory Report

paaligaad bridge On Chainage 195.658 of Rishikesh Dharasu Barkot Phool Chatti (Yamunotri) national highway

Data Yet Not Finalized

Last Rated On 22 Jun 2024

Rating 0.85%

Categorized As

XXXXX on XX-XX-XXXX

In District : Uttarkashi Under Division : NH Badkot

General

Bridge Type : Motor Bridge High Level
Structure No : 196/1
Feature Intersected : paaligaad
Name of Bridge : paaligaad bridge
Nearest Town : kuthnor
Latitude (Northing) : 30.88806000
Longitude (Easting) : 78.30500000
Construction Year : 2021
Inventory Year : 2021

Geometric

Overall length (in meter) : 36.00
Total No of Span : 1
Maximuam Span (in meter) : 36.00
Span Arragment : 1
No of Lane : 2.000
Overall Width (m) : 14.800
Carriageway Width (m) : 10.800
RS Footpath Width (m) : 1.500
LS Footpath Width (m) : 1.500
Approch Width i/c Shoulders (m) : 14.800
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 1560.000
OFL Ordinary Flood Level :
LWL Low Water Level : 1556.000
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre : 1566.685
Road Level at Centre : 1567.000
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Mild
Seismic Importance factor : 1.0
Design Loading : Class AA
Load Rating : Class AA

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Steel rolled section
Bearing type : POT PIN

Sub-Structure

Founding Strata : Bouldery
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : RCC Box type
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided