Bridge (ID- 3047 ) Inventory Report

70 m Steel Girder Bridge at Banswara On Chainage 0.090 of Banswara Bashti Basukedar motor road

Data finalized On 22 Nov 2023

By Deepak Kumar

Last Rated On 26 Nov 2024

Rating 1.46%

Categorized As

XXXXX on XX-XX-XXXX

In District : Rudraprayag Under Division : CD Ukhimath

General

Bridge Type : Motor Bridge High Level
Structure No : 1/1
Feature Intersected : Mandakini River
Name of Bridge : 70 m Steel Girder Bridge at Banswara
Nearest Town : Banswada
Latitude (Northing) : 30.45290000
Longitude (Easting) : 79.07490000
Construction Year : 2008
Inventory Year : 2023

Geometric

Overall length (in meter) : 70.00
Total No of Span : 1
Maximuam Span (in meter) : 70.00
Span Arragment : 1x1
No of Lane : 1.000
Overall Width (m) : 7.000
Carriageway Width (m) : 4.250
RS Footpath Width (m) : 0.750
LS Footpath Width (m) : 0.750
Approch Width i/c Shoulders (m) : 6.000
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 919.000
OFL Ordinary Flood Level : 916.000
LWL Low Water Level : 910.000
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre : 924.500
Road Level at Centre : 925.000
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : Truss
Superstructure Material : Steel
Wearing Coat Type : Cement Concrete
Expension Joint Type : Other
Railing/Crash Barrier type : Tubular steel
Bearing type : Roller & Rocker

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : Raft
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : Plum Concrete
Bank Protection Right Side of Up-stream : Plum Concrete
Bank Protection Left Side of Down-stream : Plum Concrete
Bank Protection Right Side of Down-stream : Plum Concrete
Floor Protection on Up-stream : NA
Floor Protection on Down-stream : NA
Tratment for Corrosion Protection (if any) : NA