Bridge (ID- 3193 ) Inventory Report

Kali Rou On Chainage 3.300 of Dehradun Sahastradhara Road (Kirsali Chowk to Sahastradhara)

Data finalized On 18 Jun 2025

By Sudarshan Singh

Last Rated On 17 Jun 2025

Rating 0.00%

Categorized As

XXXXX on XX-XX-XXXX

In District : Dehradun Under Division : PD Dehradun

General

Bridge Type : Motor Bridge High Level
Structure No : 1/4
Feature Intersected : Kali Rou
Name of Bridge : Kali Rou
Nearest Town : Sahastradhra
Latitude (Northing) : 30.38243788
Longitude (Easting) : 78.11645065
Construction Year : 2022
Inventory Year : 2023

Geometric

Overall length (in meter) : 48.00
Total No of Span : 1
Maximuam Span (in meter) : 48.00
Span Arragment : 1X48.00 m
No of Lane : 2.000
Overall Width (m) : 7.500
Carriageway Width (m) : 7.000
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 8.500
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : Truss
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Steel rolled section
Bearing type : POT PIN

Sub-Structure

Founding Strata : Bouldery
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : RCC buttressed type
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : Plum concrete work in two rows approx.40 mtr. length
Bank Protection Right Side of Up-stream : Plum concrete work in two rows approx.40 mtr. length
Bank Protection Left Side of Down-stream : N.A.
Bank Protection Right Side of Down-stream : N.A.
Floor Protection on Up-stream : N.A.
Floor Protection on Down-stream : N.A.
Tratment for Corrosion Protection (if any) : N.A.