Bridge (ID- 3203 ) Inventory Report

Feeder Canal On Chainage 26.613 of starting from its junction with NH -74 near kashipur connecting Ramnager Dhumakot Thalisain Tripalisain Pabo and Terminating at NH 119 near Bubakhal National Highway

Data finalized On 14 Dec 2023

By Qamar Alam

Last Rated On 17 Dec 2023

Rating 0.24%

Categorized As

XXXXX on XX-XX-XXXX

In District : Nanital Under Division : NH Haldwani

General

Bridge Type : Motor Bridge High Level
Structure No : 27/2
Feature Intersected : Kosi River Feeder Canal
Name of Bridge : Feeder Canal
Nearest Town : Ramnagar
Latitude (Northing) : 29.39016200
Longitude (Easting) : 79.12844300
Construction Year : 1972
Inventory Year : 2023

Geometric

Overall length (in meter) : 9.00
Total No of Span : 3
Maximuam Span (in meter) : 9.00
Span Arragment : 1x3+1x3+1x3
No of Lane : 2.000
Overall Width (m) : 7.000
Carriageway Width (m) : 7.000
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 11.000
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 0.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : Arch
Superstructure Material : Composite
Wearing Coat Type : Bituminous Concrete
Expension Joint Type : Not Provided
Railing/Crash Barrier type : Steel rolled section
Bearing type : Not Provided

Sub-Structure

Founding Strata : Bouldery
Abutment Foundation Type : Open
Pier Foundation Type : Open
No of Piers : 2
Abutment Type : Stone Masonry
Pier Type : Stone Masonry

Protection Work

Bank Protection Left Side of Up-stream : Gabian in three row provided
Bank Protection Right Side of Up-stream : Gabian in three row provided
Bank Protection Left Side of Down-stream : Gabian in three row provided
Bank Protection Right Side of Down-stream : Gabian in three row provided
Floor Protection on Up-stream : Cut-off wall and apron provided
Floor Protection on Down-stream : Cut-off wall and apron provided
Tratment for Corrosion Protection (if any) : Cut-off wall and apron provided