Data finalized On 29 Dec 2023
By Er pawan Kumar
Last Rated On 16 Jun 2024
Rating 0.00%
Categorized As
XXXXX on XX-XX-XXXX
In District : Rudraprayag Under Division : CD Ukhimath
General
Bridge Type :
Motor Bridge High Level
Structure No :
21/2
Feature Intersected :
Arsani Ghedera
Name of Bridge :
Arsani Ghedera Uniyana
Nearest Town :
Uniyana
Latitude (Northing) :
30.58326900
Longitude (Easting) :
79.12674700
Construction Year :
2008
Inventory Year :
2023
Geometric
Overall length (in meter) :
15.00
Total No of Span :
1
Maximuam Span (in meter) :
15.00
Span Arragment :
1x15.0
No of Lane :
1.000
Overall Width (m) :
4.750
Carriageway Width (m) :
3.750
RS Footpath Width (m) :
0.000
LS Footpath Width (m) :
0.000
Approch Width i/c Shoulders (m) :
5.000
Gradient (%age) :
0
Skew Angle (degree) :
0.00
Radius of Curve in Plan (if Any) :
0.00
Design Data
HFL Highest Flood Level :
1756.000
OFL Ordinary Flood Level :
1753.000
LWL Low Water Level :
1750.000
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
1759.000
Road Level at Centre :
1759.000
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition :
Moderate
Seismic Importance factor :
1.0
Design Loading :
NA
Load Rating :
NA
Super-Structure
Superstructure Type :
Truss
Superstructure Material :
Steel
Wearing Coat Type :
Other
Expension Joint Type :
Single Strip/Box Seal Joint
Railing/Crash Barrier type :
Tubular steel
Bearing type :
Elastomeric
Sub-Structure
Founding Strata :
Rocky
Abutment Foundation Type :
Open
Pier Foundation Type :
NA
No of Piers :
0
Abutment Type :
Stone Masonry
Pier Type :
NA
Protection Work
Bank Protection Left Side of Up-stream :
no protection work provided
Bank Protection Right Side of Up-stream :
no protection work provided
Bank Protection Left Side of Down-stream :
no protection work provided
Bank Protection Right Side of Down-stream :
no protection work provided
Floor Protection on Up-stream :
no protection work provided
Floor Protection on Down-stream :
no protection work provided
Tratment for Corrosion Protection (if any) :
no special treatment provided