Data Yet Not Finalized
Bridge Yet Not Rated
Categorized As
XXXXX on XX-XX-XXXX
In District : Haridwar Under Division : NH Dehradun
General
Bridge Type :
Road Over Bridge
Structure No :
255.400/10
Feature Intersected :
Roorkee-Laksar road
Name of Bridge :
Dausni
Nearest Town :
Laksar
Latitude (Northing) :
29.77801600
Longitude (Easting) :
77.98605900
Construction Year :
2018
Inventory Year :
2023
Geometric
Overall length (in meter) :
255.40
Total No of Span :
10
Maximuam Span (in meter) :
37.30
Span Arragment :
1x25.40+1x26.40+1x17.30+1x37.30+1x19.40+1x29.70+1x25.00+1x24.90+1x24.50+1x25.50
No of Lane :
2.000
Overall Width (m) :
12.000
Carriageway Width (m) :
7.000
RS Footpath Width (m) :
1.500
LS Footpath Width (m) :
1.500
Approch Width i/c Shoulders (m) :
12.000
Gradient (%age) :
3
Skew Angle (degree) :
30.00
Radius of Curve in Plan (if Any) :
0.00
Design Data
HFL Highest Flood Level :
101.500
OFL Ordinary Flood Level :
100.000
LWL Low Water Level :
100.000
Design Velocity (m/Sec) :
0.00
Design Discharge (Cumecs) :
0.00
Soffit Level at Centre :
105.500
Road Level at Centre :
105.500
Design Scour Level at Pier :
0.000
Design Scour Level at Abutments :
0.000
Exposure Condition :
Moderate
Seismic Importance factor :
1.0
Design Loading :
Class A
Load Rating :
Class A
Super-Structure
Superstructure Type :
T-beam and slab
Superstructure Material :
Reinforced concrete
Wearing Coat Type :
Bituminous Concrete
Expension Joint Type :
Single Strip/Box Seal Joint
Railing/Crash Barrier type :
Pre-cast concrete
Bearing type :
POT PIN
Sub-Structure
Founding Strata :
Hard clayey
Abutment Foundation Type :
Pile
Pier Foundation Type :
Pile
No of Piers :
8
Abutment Type :
RCC buttressed type
Pier Type :
RCC Solid
Protection Work
Bank Protection Left Side of Up-stream :
no protection work provided
Bank Protection Right Side of Up-stream :
no protection work provided
Bank Protection Left Side of Down-stream :
no protection work provided
Bank Protection Right Side of Down-stream :
no protection work provided
Floor Protection on Up-stream :
no protection work provided
Floor Protection on Down-stream :
no protection work provided
Tratment for Corrosion Protection (if any) :
no special treatment provided