Bridge (ID- 340 ) Inventory Report

MAITHGHAT BRIDGE On Chainage 121.300 of starting from its junction with NH -74 near kashipur connecting Ramnager Dhumakot Thalisain Tripalisain Pabo and Terminating at NH 119 near Bubakhal National Highway

Data finalized On 10 Jul 2023

By harish chandra singh rawat

Last Rated On 05 Nov 2024

Rating 0.08%

Categorized As

XXXXX on XX-XX-XXXX

In District : Pauri Under Division : NH Dhumakot

General

Bridge Type : Motor Bridge High Level
Structure No : 122/1
Feature Intersected : Local River
Name of Bridge : MAITHGHAT BRIDGE
Nearest Town : MAITHGHAT
Latitude (Northing) : 29.82246600
Longitude (Easting) : 79.06638889
Construction Year : 1965
Inventory Year : 2020

Geometric

Overall length (in meter) : 32.50
Total No of Span : 1
Maximuam Span (in meter) : 32.50
Span Arragment : 1X32.50
No of Lane : 1.000
Overall Width (m) : 5.100
Carriageway Width (m) : 4.500
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 5.800
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 1290.000
OFL Ordinary Flood Level : 1287.600
LWL Low Water Level : 1287.000
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre : 1293.500
Road Level at Centre : 1296.000
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : Solid slab
Superstructure Material : Steel
Wearing Coat Type : Cement Concrete
Expension Joint Type : Other
Railing/Crash Barrier type : Steel rolled section
Bearing type : Roller & Rocker

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : Well
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : Stone Masonry

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided