Bridge (ID- 3468 ) Inventory Report

Rajeswari Nagar Bridge On Chainage 1.200 of Mohkampur Rajeshwari Nursery to Divya Bihar Mianwala Road in Dehradun

Data Yet Not Finalized

Last Rated On 11 Jun 2024

Rating 0.35%

Categorized As

XXXXX on XX-XX-XXXX

In District : Dehradun Under Division : TD Rishikesh

General

Bridge Type : Motor Bridge High Level
Structure No : 1/1
Feature Intersected : Dulhni River
Name of Bridge : Rajeswari Nagar Bridge
Nearest Town : Dehradun
Latitude (Northing) : 30.27591300
Longitude (Easting) : 78.08523600
Construction Year : 2022
Inventory Year : 2022

Geometric

Overall length (in meter) : 30.00
Total No of Span : 1
Maximuam Span (in meter) : 30.00
Span Arragment : 1X30
No of Lane : 2.000
Overall Width (m) : 8.500
Carriageway Width (m) : 7.500
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 8.500
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 593.810
OFL Ordinary Flood Level : 593.460
LWL Low Water Level : 953.300
Design Velocity (m/Sec) : 0.75
Design Discharge (Cumecs) : 14.00
Soffit Level at Centre : 598.400
Road Level at Centre : 598.400
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Pre-stressed concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Cast-in-situ concrete
Bearing type : POT PIN

Sub-Structure

Founding Strata : Sandy
Abutment Foundation Type : Raft
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : RCC counterfort type
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : R.R. 1:4
Bank Protection Right Side of Up-stream : R.R. 1:4
Bank Protection Left Side of Down-stream : R.R. 1:4
Bank Protection Right Side of Down-stream : R.R. 1:4
Floor Protection on Up-stream : P.C.C.
Floor Protection on Down-stream : P.C.C.
Tratment for Corrosion Protection (if any) : no special treatment provided