Bridge (ID- 3504 ) Inventory Report

Local Nala On Chainage 158.225 of Ambala Paunta Shahib Dehradun Rishikesh (Haridwar) national highway

Data finalized On 04 Jan 2025

By Prashant Kumar Aggarwal

Bridge Yet Not Rated

Categorized As

XXXXX on XX-XX-XXXX

In District : Dehradun Under Division : NH Doiwala

General

Bridge Type : Motor Bridge High Level
Structure No : 159/1
Feature Intersected : Local Nala
Name of Bridge : Local Nala
Nearest Town : Dehradun
Latitude (Northing) : 30.28870700
Longitude (Easting) : 78.02047400
Construction Year : 2023
Inventory Year : 2025

Geometric

Overall length (in meter) : 10.00
Total No of Span : 1
Maximuam Span (in meter) : 10.00
Span Arragment : 1x10m
No of Lane : 4.000
Overall Width (m) : 17.000
Carriageway Width (m) : 15.000
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 1.500
Approch Width i/c Shoulders (m) : 7.500
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 0.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : Single/Multi-cell Box
Superstructure Material : Reinforced concrete
Wearing Coat Type : Bituminous Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Cast-in-situ concrete
Bearing type : Not Provided

Sub-Structure

Founding Strata : Bouldery
Abutment Foundation Type : Raft
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : RCC Box type
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : Stone Masonry Wall
Bank Protection Right Side of Up-stream : Stone Masonry Wall
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : Apron Provided
Tratment for Corrosion Protection (if any) : Apron Provided