Bridge (ID- 3521 ) Inventory Report

pd ranikhet On Chainage 26.125 of Bikhyasain Deghat Bungidhar Mehalchori Bachuwaban Chokhutiya state highway

Data Yet Not Finalized

Bridge Yet Not Rated

Categorized As

XXXXX on XX-XX-XXXX

In District : Almora Under Division : PD Ranikhet

General

Bridge Type : Motor Bridge Submersible
Structure No : 26/1
Feature Intersected : Babaliya Gadhera
Name of Bridge : pd ranikhet
Nearest Town : Patharkhola
Latitude (Northing) : 29.86557600
Longitude (Easting) : 79.21705500
Construction Year : 1950
Inventory Year : 2025

Geometric

Overall length (in meter) : 10.90
Total No of Span : 1
Maximuam Span (in meter) : 10.90
Span Arragment : 1X10.90
No of Lane : 1.000
Overall Width (m) : 4.500
Carriageway Width (m) : 4.500
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 4.500
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 2000.000
OFL Ordinary Flood Level : 1500.000
LWL Low Water Level : 1100.000
Design Velocity (m/Sec) : 3.64
Design Discharge (Cumecs) : 0.00
Soffit Level at Centre : 3.000
Road Level at Centre : 5.000
Design Scour Level at Pier : 0.000
Design Scour Level at Abutments : 0.000
Exposure Condition : Moderate
Seismic Importance factor : 0.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : other
Bearing type : Not Provided

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Raft
Pier Foundation Type : Open
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : Stone Masonry

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided