Bridge (ID- 3845 ) Inventory Report

36 mtr span steel Girder Motor bridge at km 1 of Jaal bend to chilond motor road

Data Yet Not Finalized

Last Rated On 03 Jul 2026

Rating 0.08%

Categorized As

XXXXX on XX-XX-XXXX

In District : Rudraprayag Under Division : CD Ukhimath

General

Bridge Type : Motor Bridge High Level
Structure No : 1/1
Feature Intersected : Saraswati River
Name of Bridge : 36 mtr span steel Girder Motor bridge at km 1 of Jaal bend to chilond motor road
Nearest Town : Kalimath kotma
Latitude (Northing) : 30.60416900
Longitude (Easting) : 79.07613900
Construction Year : 2025
Inventory Year : 2026
Work Code(s) : --

Geometric

Overall length (in meter) : 36.00
Total No of Span : 1
Maximuam Span (in meter) : 36.00
Span Arragment : 1X36.00 M
No of Lane : 1.000
Overall Width (m) : 5.250
Carriageway Width (m) : 4.250
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 5.250
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 1566.000
OFL Ordinary Flood Level : 1574.190
LWL Low Water Level : 1559.780
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre : 1571.190
Road Level at Centre : 1571.190
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : Truss
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Tubular steel
Bearing type : Elastomeric

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Raft
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided