Bridge (ID- 3850 ) Inventory Report

Changin Kucholi Kuthkhal MR On Chainage 8.150 of Changin Kucholi Kuthkhal motor road (ODR)

Data finalized On 21 May 2026

By Ashok Kumar/Santosh Bhardwaj

Last Rated On 26 May 2026

Rating 0.00%

Categorized As

XXXXX on XX-XX-XXXX

In District : Pauri Under Division : CD Pabo

General

Bridge Type : Motor Bridge High Level
Structure No : 2
Feature Intersected : Local Gadera
Name of Bridge : Changin Kucholi Kuthkhal MR
Nearest Town : Kucholi
Latitude (Northing) : 30.10319500
Longitude (Easting) : 79.10190700
Construction Year : 2005
Inventory Year : 2026
Work Code(s) : --

Geometric

Overall length (in meter) : 7.00
Total No of Span : 1
Maximuam Span (in meter) : 7.00
Span Arragment : 1x7
No of Lane : 1.000
Overall Width (m) : 4.800
Carriageway Width (m) : 4.300
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 5.950
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 104.000
OFL Ordinary Flood Level : 102.000
LWL Low Water Level : 100.000
Design Velocity (m/Sec) : 2.50
Design Discharge (Cumecs) : 20.00
Soffit Level at Centre : 1.000
Road Level at Centre : 1.000
Design Scour Level at Pier : 1.000
Design Scour Level at Abutments : 1.000
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : Solid slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Not Provided
Expension Joint Type : Not Provided
Railing/Crash Barrier type : Cast-in-situ concrete
Bearing type : Not Provided

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided