Data finalized On 05 Jun 2026
By SMT SHALU VERMA AAE
Last Rated On 18 Jun 2026
Rating 0.00%
Categorized As
XXXXX on XX-XX-XXXX
In District : Pauri Under Division : CD Dugadda
General
Bridge Type :
Motor Bridge High Level
Structure No :
5/1
Feature Intersected :
GADERA
Name of Bridge :
TELI SHROT BOX CULVERT BRIDGE
Nearest Town :
KISHANPUR
Latitude (Northing) :
29.78184300
Longitude (Easting) :
78.41977800
Construction Year :
2026
Inventory Year :
2026
Work Code(s) :
--
Geometric
Overall length (in meter) :
30.00
Total No of Span :
3
Maximuam Span (in meter) :
10.00
Span Arragment :
3X10
No of Lane :
2.000
Overall Width (m) :
8.000
Carriageway Width (m) :
7.500
RS Footpath Width (m) :
0.000
LS Footpath Width (m) :
0.000
Approch Width i/c Shoulders (m) :
8.000
Gradient (%age) :
0
Skew Angle (degree) :
0.00
Radius of Curve in Plan (if Any) :
0.00
Design Data
HFL Highest Flood Level :
410.500
OFL Ordinary Flood Level :
409.181
LWL Low Water Level :
409.181
Design Velocity (m/Sec) :
0.00
Design Discharge (Cumecs) :
56.00
Soffit Level at Centre :
408.375
Road Level at Centre :
413.000
Design Scour Level at Pier :
0.000
Design Scour Level at Abutments :
0.000
Exposure Condition :
Moderate
Seismic Importance factor :
1.0
Design Loading :
Class A
Load Rating :
Class A
Super-Structure
Superstructure Type :
Solid slab
Superstructure Material :
Reinforced concrete
Wearing Coat Type :
Cement Concrete
Expension Joint Type :
Filler
Railing/Crash Barrier type :
Cast-in-situ concrete
Bearing type :
Not Provided
Sub-Structure
Founding Strata :
Bouldery
Abutment Foundation Type :
Raft
Pier Foundation Type :
Raft
No of Piers :
2
Abutment Type :
RCC Box type
Pier Type :
RCC Solid
Protection Work
Bank Protection Left Side of Up-stream :
Concrete and stone masonry wall.
Bank Protection Right Side of Up-stream :
no protection work provided
Bank Protection Left Side of Down-stream :
Concrete and stone masonry wall.
Bank Protection Right Side of Down-stream :
stone masonry wall.
Floor Protection on Up-stream :
Rigid floor with RCC curtain wall
Floor Protection on Down-stream :
Rigid floor with RCC curtain wall
Tratment for Corrosion Protection (if any) :
no special treatment provided