Bridge (ID- 3870 ) Inventory Report

थत्यूड़- मुगलोड़ी मोटर मार्ग कि0मी0-10 है0मी0 6-8 On Chainage 9.600 of Thatyud Muglodi road (VR)

Data finalized On 09 Sep 2026

By Mamta Rawat

Last Rated On 02 Jul 2026

Rating 0.47%

Categorized As

XXXXX on XX-XX-XXXX

In District : Tehri Under Division : TD Thatyur

General

Bridge Type : Motor Bridge High Level
Structure No : 1/1
Feature Intersected : local river
Name of Bridge : थत्यूड़- मुगलोड़ी मोटर मार्ग कि0मी0-10 है0मी0 6-8
Nearest Town : mungalodi
Latitude (Northing) : 30.54592587
Longitude (Easting) : 78.15144293
Construction Year : 2018
Inventory Year : 2025
Work Code(s) : --

Geometric

Overall length (in meter) : 11.60
Total No of Span : 1
Maximuam Span (in meter) : 11.60
Span Arragment : 1X11.60
No of Lane : 1.000
Overall Width (m) : 7.000
Carriageway Width (m) : 6.400
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 5.950
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 0.0
Design Loading : NA
Load Rating : NA

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Filler
Railing/Crash Barrier type : Steel rolled section
Bearing type : Roller & Rocker

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided