Bridge (ID- 399 ) Inventory Report

Dhela Bridge On Chainage 14.100 of Kashipur main motor road

Data finalized On 14 Jan 2022

By Nafees Ahmad

Last Rated On 16 Jun 2024

Rating 0.95%

Categorized As

XXXXX on XX-XX-XXXX

In District : Udham Singh Nagar Under Division : CD Kashipur

General

Bridge Type : Motor Bridge High Level
Structure No : 1/1
Feature Intersected : Dhela
Name of Bridge : Dhela Bridge
Nearest Town : Kashipur
Latitude (Northing) : 29.30027700
Longitude (Easting) : 78.96861100
Construction Year : 1986
Inventory Year : 2020

Geometric

Overall length (in meter) : 149.22
Total No of Span : 5
Maximuam Span (in meter) : 30.05
Span Arragment : 3x30.05m + 2x29.536m
No of Lane : 2.000
Overall Width (m) : 8.100
Carriageway Width (m) : 7.500
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 8.100
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Pre-stressed concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Not Provided
Railing/Crash Barrier type : Steel rolled section
Bearing type : Roller & Rocker

Sub-Structure

Founding Strata : Sandy
Abutment Foundation Type : Well
Pier Foundation Type : Well
No of Piers : 1
Abutment Type : other
Pier Type : other

Protection Work

Bank Protection Left Side of Up-stream : Gabian Three row provided
Bank Protection Right Side of Up-stream : Gabian Three row provided
Bank Protection Left Side of Down-stream : Gabian Single row provided
Bank Protection Right Side of Down-stream : Gabian Single row provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided