Data finalized On 06 Aug 2022
By Jagdish Papney
Last Rated On 03 Jun 2024
Rating 0.55%
Categorized As
XXXXX on XX-XX-XXXX
In District : Bageshwar Under Division : CD Kapkot
General
Bridge Type :
Motor Bridge High Level
Structure No :
36/1
Feature Intersected :
Simi Local Gadhera
Name of Bridge :
12.40 Mtr Span motor Bridge in Jarti
Nearest Town :
jarti
Latitude (Northing) :
29.89737800
Longitude (Easting) :
79.93143600
Construction Year :
2011
Inventory Year :
2011
Geometric
Overall length (in meter) :
12.40
Total No of Span :
1
Maximuam Span (in meter) :
12.40
Span Arragment :
1x12.40
No of Lane :
1.000
Overall Width (m) :
4.250
Carriageway Width (m) :
4.250
RS Footpath Width (m) :
0.000
LS Footpath Width (m) :
0.000
Approch Width i/c Shoulders (m) :
6.000
Gradient (%age) :
0
Skew Angle (degree) :
0.00
Radius of Curve in Plan (if Any) :
0.00
Design Data
HFL Highest Flood Level :
1101.000
OFL Ordinary Flood Level :
1100.250
LWL Low Water Level :
1100.000
Design Velocity (m/Sec) :
4.00
Design Discharge (Cumecs) :
200.00
Soffit Level at Centre :
1104.500
Road Level at Centre :
1105.000
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition :
Moderate
Seismic Importance factor :
0.0
Design Loading :
Class B
Load Rating :
Class B
Super-Structure
Superstructure Type :
Truss
Superstructure Material :
Steel
Wearing Coat Type :
Cement Concrete
Expension Joint Type :
Single Strip/Box Seal Joint
Railing/Crash Barrier type :
Steel rolled section
Bearing type :
Roller & Rocker
Sub-Structure
Founding Strata :
Bouldery
Abutment Foundation Type :
Raft
Pier Foundation Type :
NA
No of Piers :
0
Abutment Type :
Stone Masonry
Pier Type :
NA
Protection Work
Bank Protection Left Side of Up-stream :
no protection work provided
Bank Protection Right Side of Up-stream :
no protection work provided
Bank Protection Left Side of Down-stream :
no protection work provided
Bank Protection Right Side of Down-stream :
no protection work provided
Floor Protection on Up-stream :
no protection work provided
Floor Protection on Down-stream :
no protection work provided
Tratment for Corrosion Protection (if any) :
no special treatment provided