Bridge (ID- 506 ) Inventory Report

Garjiya Pedestrain Bridge on Kosi River On Chainage 0.900 of Ranikhet Ramnagar Road to Garjiya Mandir Road

Data finalized On 24 Dec 2022

By S.P. Dhasmana

Last Rated On 03 Jun 2024

Rating 0.11%

Categorized As

XXXXX on XX-XX-XXXX

In District : Nanital Under Division : CD Ramnagar

General

Bridge Type : Pedestrain Bridge
Structure No : 1/2
Feature Intersected : Koshi River
Name of Bridge : Garjiya Pedestrain Bridge on Kosi River
Nearest Town : Ramnaga
Latitude (Northing) : 29.49410000
Longitude (Easting) : 79.14030000
Construction Year : 2011
Inventory Year : 2021

Geometric

Overall length (in meter) : 72.00
Total No of Span : 2
Maximuam Span (in meter) : 36.00
Span Arragment : 2x36m
No of Lane : 2.000
Overall Width (m) : 5.500
Carriageway Width (m) : 5.000
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 5.000
Gradient (%age) : 2
Skew Angle (degree) : 3.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Footpath Live Load
Load Rating : Footpath Live Load

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Reinforced Elastomeric Joint
Railing/Crash Barrier type : Steel rolled section
Bearing type : Elastomeric

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Well
Pier Foundation Type : Open
No of Piers : 1
Abutment Type : RCC Box type
Pier Type : RCC Solid

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided