Data Yet Not Finalized
Last Rated On 11 Nov 2023
Rating 5.87%
Categorized As
XXXXX on XX-XX-XXXX
In District : Udham Singh Nagar Under Division : CD Khatima
General
Bridge Type :
Motor Bridge High Level
Structure No :
1/7
Feature Intersected :
Sharda River at Khatima Melaghat
Name of Bridge :
Sharda River at Khatima Melaghat
Nearest Town :
Khatima
Latitude (Northing) :
28.86614200
Longitude (Easting) :
80.03530300
Construction Year :
1927
Inventory Year :
2021
Geometric
Overall length (in meter) :
33.00
Total No of Span :
1
Maximuam Span (in meter) :
33.00
Span Arragment :
1x33m
No of Lane :
2.000
Overall Width (m) :
7.500
Carriageway Width (m) :
7.500
RS Footpath Width (m) :
0.000
LS Footpath Width (m) :
0.000
Approch Width i/c Shoulders (m) :
12.000
Gradient (%age) :
0
Skew Angle (degree) :
0.00
Radius of Curve in Plan (if Any) :
0.00
Design Data
HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition :
Moderate
Seismic Importance factor :
1.0
Design Loading :
Class A
Load Rating :
Class A
Super-Structure
Superstructure Type :
T-beam and slab
Superstructure Material :
Pre-stressed concrete
Wearing Coat Type :
Cement Concrete
Expension Joint Type :
Single Strip/Box Seal Joint
Railing/Crash Barrier type :
Pre-cast concrete
Bearing type :
Elastomeric
Sub-Structure
Founding Strata :
Sandy
Abutment Foundation Type :
Raft
Pier Foundation Type :
NA
No of Piers :
0
Abutment Type :
RCC Box type
Pier Type :
NA
Protection Work
Bank Protection Left Side of Up-stream :
no protection work provided
Bank Protection Right Side of Up-stream :
no protection work provided
Bank Protection Left Side of Down-stream :
no protection work provided
Bank Protection Right Side of Down-stream :
no protection work provided
Floor Protection on Up-stream :
no protection work provided
Floor Protection on Down-stream :
no protection work provided
Tratment for Corrosion Protection (if any) :
no special treatment provided