Bridge (ID- 66 ) Inventory Report

Malli Sethi bridge On Chainage 50.125 of Ramnagar Bhandarpani Amgari Bhorakote Aakhudunga Talli Sati Betalghat Ratora Visalkote Jaina Richi Billekh state highway

Data finalized On 26 Aug 2022

By RAKESH CHANDRA ARYA

Last Rated On 20 Dec 2024

Rating 0.66%

Categorized As

XXXXX on XX-XX-XXXX

In District : Nanital Under Division : CD Nainital

General

Bridge Type : Motor Bridge High Level
Structure No : 51/2
Feature Intersected : Kosi River
Name of Bridge : Malli Sethi bridge
Nearest Town : Amel
Latitude (Northing) : 29.49557800
Longitude (Easting) : 79.47820800
Construction Year : 2011
Inventory Year : 2020

Geometric

Overall length (in meter) : 250.00
Total No of Span : 5
Maximuam Span (in meter) : 50.00
Span Arragment : 5x50
No of Lane : 2.000
Overall Width (m) : 7.200
Carriageway Width (m) : 6.700
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 5.950
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : Solid slab
Superstructure Material : Pre-stressed concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Reinforced Elastomeric Joint
Railing/Crash Barrier type : Cast-in-situ concrete
Bearing type : other

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Well
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : RCC buttressed type
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided