Bridge (ID- 676 ) Inventory Report

Bhankoli pahuch maarg

Data finalized On 23 Nov 2022

By JE Ravindra Singh Bisht

Last Rated On 29 May 2024

Rating 2.36%

Categorized As

XXXXX on XX-XX-XXXX

In District : Uttarkashi Under Division : CD Badkote

General

Bridge Type : Pedestrain Bridge
Structure No : 2/1
Feature Intersected : Yamuna river
Name of Bridge : Bhankoli pahuch maarg
Nearest Town : Chamrota bhankoli
Latitude (Northing) : 30.75640000
Longitude (Easting) : 78.09430000
Construction Year : 1988
Inventory Year : 2022

Geometric

Overall length (in meter) : 58.00
Total No of Span : 1
Maximuam Span (in meter) : 58.00
Span Arragment : 1×58
No of Lane : 1.000
Overall Width (m) : 1.600
Carriageway Width (m) : 1.600
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 1.600
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Footpath Live Load
Load Rating : Footpath Live Load

Super-Structure

Superstructure Type : Suspension
Superstructure Material : Steel
Wearing Coat Type : Cement Concrete
Expension Joint Type : Other
Railing/Crash Barrier type : Steel rolled section
Bearing type : Not Provided

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided