Data Yet Not Finalized
Last Rated On 20 Nov 2024
Rating 0.64%
Categorized As
XXXXX on XX-XX-XXXX
In District : Haridwar Under Division : CD Roorkee
General
Bridge Type :
Motor Bridge High Level
Structure No :
S.No. 02
Feature Intersected :
Ramtau River
Name of Bridge :
Dhanauri Bridge on Ratmau
Nearest Town :
Dhanauri
Latitude (Northing) :
29.94029000
Longitude (Easting) :
77.95024000
Construction Year :
2010
Inventory Year :
2011
Geometric
Overall length (in meter) :
220.00
Total No of Span :
1
Maximuam Span (in meter) :
24.45
Span Arragment :
9x 24.445
No of Lane :
1.000
Overall Width (m) :
7.500
Carriageway Width (m) :
7.500
RS Footpath Width (m) :
0.000
LS Footpath Width (m) :
0.000
Approch Width i/c Shoulders (m) :
7.500
Gradient (%age) :
3
Skew Angle (degree) :
0.00
Radius of Curve in Plan (if Any) :
0.00
Design Data
HFL Highest Flood Level :
269.600
OFL Ordinary Flood Level :
266.000
LWL Low Water Level :
265.875
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
2025.00
Soffit Level at Centre :
270.000
Road Level at Centre :
273.650
Design Scour Level at Pier :
265.275
Design Scour Level at Abutments :
271.250
Exposure Condition :
Moderate
Seismic Importance factor :
1.0
Design Loading :
Class A
Load Rating :
Class A
Super-Structure
Superstructure Type :
T-beam and slab
Superstructure Material :
Pre-stressed concrete
Wearing Coat Type :
Cement Concrete
Expension Joint Type :
Single Strip/Box Seal Joint
Railing/Crash Barrier type :
Cast-in-situ concrete
Bearing type :
POT PIN
Sub-Structure
Founding Strata :
Sandy
Abutment Foundation Type :
Well
Pier Foundation Type :
Well
No of Piers :
8
Abutment Type :
other
Pier Type :
other
Protection Work
Bank Protection Left Side of Up-stream :
protection work provided
Bank Protection Right Side of Up-stream :
protection work provided
Bank Protection Left Side of Down-stream :
protection work provided
Bank Protection Right Side of Down-stream :
protection work provided
Floor Protection on Up-stream :
no protection work provided
Floor Protection on Down-stream :
protection work provided
Tratment for Corrosion Protection (if any) :
no special treatment provided