Bridge (ID- 730 ) Inventory Report

Bhagwanpur Bridge On Chainage 0.500 of Link road from Susadi Khurd to Susadi Khurd Susadi via Primary School

Data Yet Not Finalized

Last Rated On 20 Nov 2024

Rating 0.60%

Categorized As

XXXXX on XX-XX-XXXX

In District : Haridwar Under Division : CD Roorkee

General

Bridge Type : Motor Bridge High Level
Structure No : 1
Feature Intersected : Solani River
Name of Bridge : Bhagwanpur Bridge
Nearest Town : Bhagwanpur
Latitude (Northing) : 29.95120100
Longitude (Easting) : 77.81875600
Construction Year :
Inventory Year : 2020

Geometric

Overall length (in meter) : 540.00
Total No of Span : 30
Maximuam Span (in meter) : 28.00
Span Arragment : 18*30
No of Lane : 2.000
Overall Width (m) : 8.500
Carriageway Width (m) : 7.500
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 12.000
Gradient (%age) : 3
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 200.000
OFL Ordinary Flood Level :
LWL Low Water Level : 197.394
Design Velocity (m/Sec) :
Design Discharge (Cumecs) : 2265.36
Soffit Level at Centre : 203.475
Road Level at Centre : 205.500
Design Scour Level at Pier : 186.290
Design Scour Level at Abutments : 191.290
Exposure Condition : Moderate
Seismic Importance factor : 1.2
Design Loading : Class AA
Load Rating : Class AA

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Pre-stressed concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Pre-cast concrete
Bearing type : other

Sub-Structure

Founding Strata : Sandy
Abutment Foundation Type : Well
Pier Foundation Type : Well
No of Piers : 17
Abutment Type : RCC spill through type
Pier Type : RCC Solid

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided