Bridge (ID- 733 ) Inventory Report

Hasanpur- Madanpur bridge On Chainage 2.250 of Village Mandawar to Hasanpur Madanpur Ghat road

Data Yet Not Finalized

Last Rated On 20 Nov 2024

Rating 0.21%

Categorized As

XXXXX on XX-XX-XXXX

In District : Haridwar Under Division : CD Roorkee

General

Bridge Type : Motor Bridge High Level
Structure No : 1
Feature Intersected : Solani River
Name of Bridge : Hasanpur- Madanpur bridge
Nearest Town : Bhagwanpur
Latitude (Northing) : 30.01515100
Longitude (Easting) : 77.78143500
Construction Year : 2010
Inventory Year : 2020

Geometric

Overall length (in meter) : 300.00
Total No of Span : 12
Maximuam Span (in meter) : 25.00
Span Arragment : 12*25
No of Lane : 2.000
Overall Width (m) : 8.500
Carriageway Width (m) : 7.500
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 7.500
Gradient (%age) : 3
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 199.975
OFL Ordinary Flood Level : 198.500
LWL Low Water Level : 197.200
Design Velocity (m/Sec) : 2.35
Design Discharge (Cumecs) : 1600.00
Soffit Level at Centre : 203.500
Road Level at Centre : 106.110
Design Scour Level at Pier : 188.975
Design Scour Level at Abutments : 192.825
Exposure Condition : Moderate
Seismic Importance factor : 1.2
Design Loading : Class AA
Load Rating : Class AA

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Not Provided
Railing/Crash Barrier type : Pre-cast concrete
Bearing type : Not Provided

Sub-Structure

Founding Strata : Sandy
Abutment Foundation Type : Well
Pier Foundation Type : Well
No of Piers : 11
Abutment Type : RCC counterfort type
Pier Type : RCC Solid

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided